Garp Timers; Disable - Dell Force10 Z9000 Reference Manual

Ftos command line reference guide for the z9000 system ftos 9.1.(0.0)
Hide thumbs Also See for Force10 Z9000:
Table of Contents

Advertisement

disable

Globally disable GVRP.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
disable
To re-enable GVRP, use the no disable command.
Defaults
Enabled.
Command Modes
CONFIGURATION-GVRP
Command History
Version 8.3.11.1
Version 8.3.7.0
Version 7.6.1.0
Related
gvrp enable
Commands
protocol gvrp

garp timers

Set the intervals (in milliseconds) for sending GARP messages.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
garp timers {join | leave | leave-all}
To return to the previous setting, use the no garp timers {join | leave |
leave-all} command.
Parameters
join
leave
leave-all
652
Introduced on the Z9000.
Introduced on the S4810.
Introduced on C-Series, E-Series, and S-Series
– enables GVRP on physical interfaces and LAGs.
– access GVRP protocol.
Enter the keyword join followed by the number of milliseconds to
configure the join time. The range is 100 to 147483647 milliseconds.
The default is 200 milliseconds.
NOTE: Designate the milliseconds in multiples of 100.
Enter the keyword leave followed by the number of milliseconds to
configure the leave time. The range is 100 to 2147483647 milliseconds.
The default is 600 milliseconds.
NOTE: Designate the milliseconds in multiples of 100.
Enter the keywords leave-all followed by the number of
milliseconds to configure the leave-all time. The range is 100 to
2147483647 milliseconds. The default is 1000 milliseconds.

Advertisement

Table of Contents
loading

Table of Contents