Version 8.5.1.0
Version 8.2.1.0
Version 8.1.1.0
Version 7.6.1.0
Version 7.5.1.0
E-Series legacy
command
Usage
The following describes the show interfaces switchport command for the Example
Information
below.
Items
Name
802.1QTagged
Vlan membership
Example
FTOS#show interfaces switchport
Name: GigabitEthernet 13/0
802.1QTagged: Hybrid
Vlan membership:
Vlan
Native VlanId: 20
Name: GigabitEthernet 13/1
802.1QTagged: True
Vlan membership:
Vlan
Name: GigabitEthernet 13/2
802.1QTagged: True
Vlan membership:
Vlan
Name: GigabitEthernet 13/3
802.1QTagged: True
Vlan membership:
Vlan
--More--
EXEC
EXEC Privilege
Introduced on the Z9000.
Added support for 4-port 40G line cards on ExaScale.
Added support for 4093 VLANs on E-Series ExaScale.
Introduced on the E-Series ExaScale.
Support added for hybrid port/native VLAN, introduced on the S-
Series.
Introduced on the C-Series.
Description
Displays the interface's type, slot, and port number.
Displays whether if the VLAN tagged ("True"), untagged ("False"), or
hybrid ("Hybrid"), which supports both untagged and tagged VLANs
by port 13/0.
Lists the VLANs to which the interface is a member. Starting with
FTOS version 7.6.1, this field can display native VLAN membership by
port 13/0.
2, Vlan 20
2
2
2
739