Dell Force10 Z9000 Reference Manual page 172

Ftos command line reference guide for the z9000 system ftos 9.1.(0.0)
Hide thumbs Also See for Force10 Z9000:
Table of Contents

Advertisement

E-Series
Usage
show rpm
Information
output Field
Status
Next Boot
Card Type
Hardware Rev
Num Ports
Up Time
Last Restart
FTOS Version
Jumbo Capable
CP Boot Flash
RP1 Boot Flash
172
Original command.
Description
Displays the RPM's status.
Displays whether the RPM is to be brought online at the next system
reload.
Displays the RPM catalog number.
Displays the E-Series chipset hardware revision level: 1.0 (non-
Jumbo); 1.5 (Jumbo-enabled); 2.0 (or above is TeraScale).
Displays the number of active ports.
Displays the number of hours and minutes since the RPM's last
reboot.
States the reason for the last RPM reboot.
C-Series possible values:
"normal power-cycle" (reset power-cycle command)
"reset by master" (peer RPM reset by master RPM)
"over temperature shutdown"
"power supply failed"
E-Series possible values:
"normal power-cycle" (insufficient power, normal power
cycle)
"reset by user" (automatic failover, software reload of both
RPMs, or master RPM resetting peer)
"force-failover" (redundancy force-failover
command)
Displays the operating software version.
Displays a Yes or No indicating if the RPM is capable of sending and
receiving Jumbo frames.
This field does not indicate if the chassis is in Jumbo mode; for that
determination, use the show chassis brief command.
Displays the two possible Boot Flash versions for the control
processor. The [Booted] keyword next to the version states which
version was used at system boot.
Displays the two possible Boot Flash versions for the Routing
Processor 1. The [Booted] keyword next to the version states which
version was used at system boot.

Advertisement

Table of Contents
loading

Table of Contents