test tone-clock

test tone-clock
The test tone/clock command performs hardware diagnostic tests on a
technician-specified tone or clock circuit pack.
Action/Object
Qualifier
test
location
tone-clock
short
long
repeat
number
clear
schedule
1
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
2
Refer to the Report Scheduler and System Printer feature specification for more details.
555-233-123
Qualifier Description
PCSS
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
How many times each test in the
sequence is repeated (1-100)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue and
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.
Examples:
test tone-clock 01a l
test tone-clock 01b l schedule
Logins
Defaults
init
Test
inads
Sequence
craft
= short;
Repeat =
1
1
2
Issue 4 May 2002