Analog-to-digital converter (ADC)
15.3.14

Stopping an ongoing conversion (ADSTP)

The software can decide to stop any ongoing conversions by setting ADSTP = 1 in the
ADC_CR register.
This resets the ADC operation and the ADC is idle, ready for a new operation.
When the ADSTP bit is set by software, any ongoing conversion is aborted and the result is
discarded (ADC_DR register is not updated with the current conversion).
The scan sequence is also aborted and reset (meaning that restarting the ADC would re-
start a new sequence).
Once this procedure is complete, the ADSTP and ADSTART bits are both cleared by
hardware and the software must wait until ADSTART=0 before starting new conversions.
ADC state
ADSTART
ADSTOP
ADC_DR
15.4
Conversion on external trigger and trigger polarity (EXTSEL,
EXTEN)
A conversion or a sequence of conversion can be triggered either by software or by an
external event (for example timer capture). If the EXTEN[1:0] control bits are not equal to
"0b00", then external events are able to trigger a conversion with the selected polarity. The
trigger selection is effective once software has set bit ADSTART = 1.
Any hardware triggers which occur while a conversion is ongoing are ignored.
If bit ADSTART = 0, any hardware triggers which occur are ignored.
Table 72
polarity.
Trigger detection disabled
Detection on rising edge
Detection on falling edge
Detection on both rising and falling edges
Note:
The polarity of the external trigger can be changed only when the ADC is not converting
(ADSTART = 0).
The EXTSEL[2:0] control bits are used to select which of 8 possible events can trigger
conversions.
358/1390

Figure 39. Stopping an ongoing conversion

RDY
SAMPLING CH(N)
set by SW
provides the correspondence between the EXTEN[1:0] values and the trigger

Table 72. Configuring the trigger polarity

Source
CONVERTING CH(N)
DATA N-1
RM0444 Rev 5
RDY
cleared by HW
set by SW
cleared by HW
EXTEN[1:0]
00
01
10
11
RM0444
MS30337V1