PAD CONTROL
GPL3CON[1]
[7:4]
GPL3CON[2]
[11:8]
GPL3CON[3]
[15:12]
GPL3CON[4]
[19:16]
GPL3CON[5]
[23:20]
GPL3CON[6]
[27:24]
GPL3CON[7]
[31:28]
5.1.34
Port Group GPL4 Configuration Register (GPL4CON, R/W, Address = 0xE030_03A0)
Field
GPL4CON[0]
GPL4CON[1]
GPL4CON[2]
GPL4CON[3]
GPL4CON[4]
5.2 PORT DATA & PULLING REGISTER
5.2.1 Port Data Registers
• GPA0DAT, R/W, Address = 0xE030_0004
• GPA1DAT, R/W, Address = 0xE030_0024
• GPBDAT, R/W, Address = 0xE030_0044
• GPCDAT, R/W, Address = 0xE030_0064
• GPDDAT, R/W, Address = 0xE030_0084
• GPE0DAT, R/W, Address = 0xE030_00A4
• GPE1DAT, R/W, Address = 0xE030_00C4
• GPF0DAT, R/W, Address = 0xE030_00E4
• GPF1DAT, R/W, Address = 0xE030_0104
• GPF2DAT, R/W, Address = 0xE030_0124
• GPF3DAT, R/W, Address = 0xE030_0144
• GPG0DAT, R/W, Address = 0xE030_0164
• GPG1DAT, R/W, Address = 0xE030_0184
• GPG2DAT, R/W, Address = 0xE030_01A4
• GPG3DAT, R/W, Address = 0xE030_01C4
• GPH0DAT, R/W, Address = 0xE030_0C04.
• GPH1DAT, R/W, Address = 0xE030_0C24.
• GPH2DAT, R/W, Address = 0xE030_0C44.
2.2-44
0000 = Input, 0001 = Output, 0010 = EBI_D[4]
0000 = Input, 0001 = Output, 0010 = EBI_D[5]
0000 = Input, 0001 = Output, 0010 = EBI_D[6]
0000 = Input, 0001 = Output, 0010 = EBI_D[7]
0000 = Input, 0001 = Output, 0010 = EBI_D[8]
0000 = Input, 0001 = Output, 0010 = EBI_D[9]
0000 = Input, 0001 = Output, 0010 = EBI_D[10]
Bit
[3:0]
0000 = Input, 0001 = Output, 0010 = EBI_D[11]
[7:4]
0000 = Input, 0001 = Output, 0010 = EBI_D[12]
[11:8]
0000 = Input, 0001 = Output, 0010 = EBI_D[13]
[15:12]
0000 = Input, 0001 = Output, 0010 = EBI_D[14]
[19:16]
0000 = Input, 0001 = Output, 0010 = EBI_D[15]
S5PC100 USER'S MANUAL (REV1.0)
Description
0010
0010
0010
0010
0010
0010
0010
Reset Value
0010
0010
0010
0010
0010

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents