PAD CONTROL
5.6.11
Wake-up Interrupt Filter Configuration Register24_27 (WKUP_INT_FLTCON24_27, R/W, Address
= 0xE030_0E98)
Field
FLTEN24_27[3]
FLTSEL24_27[3]
EINT24_27[3]
FLTEN24_27[2]
FLTSEL24_27[2]
EINT24_27[2]
FLTEN24_27[1]
FLTSEL24_27[1]
EINT24_27[1]
FLTEN24_27[0]
FLTSEL24_27[0]
EINT24_27[0]
2.2-94
Bit
Filter Enable for WKUP_INT[27]
[31]
0 = disables 1 = enables
Filter Selection for WKUP_INT[27]
[30]
0 = delay filter 1 = digital filter(clock count)
Filtering width for WKUP_INT[27]
[29:24]
This value is valid if FLTSEL3 is1.
Filter Enable for WKUP_INT[26]
[23]
0 = disables 1 = enables
Filter Selection for WKUP_INT[26]
[22]
0 = delay filter 1 = digital filter(clock count)
Filtering width for WKUP_INT[26]
[21:16]
This value is valid if FLTSEL3 is1.
Filter Enable for WKUP_INT[25]
[15]
0 = disables 1 = enables
Filter Selection for WKUP_INT[25]
[14]
0 = delay filter 1 = digital filter(clock count)
Filtering width for WKUP_INT[25]
[13:8]
This value is valid if FLTSEL3 is1.
Filter Enable for WKUP_INT[24]
[7]
0 = disables 1 = enables
Filter Selection for WKUP_INT[24]
[6]
0 = delay filter 1 = digital filter(clock count)
Filtering width for WKUP_INT[24]
[5:0]
This value is valid if FLTSEL3 is1.
S5PC100 USER'S MANUAL (REV1.0)
Description
Reset Value
0
0
000
0
0
000
0
0
000
0
0
000