5.6.8 Wake-up Interrupt Filter Configuration Register12_15 (WKUP_INT_FLTCON12_15, R/W, Address =
0xE030_0E8C)
Field
FLTEN12_15[7]
FLTSEL12_15[7]
EINT12_15[7]
FLTEN12_15[6]
FLTSEL12_15[6]
EINT12_15[6]
FLTEN12_15[5]
FLTSEL12_15[5]
EINT12_15[5]
FLTEN12_15[4]
FLTSEL12_15[4]
EINT12_15[4]
Bit
Filter Enable for WKUP_INT[15]
[31]
0 = disables 1 = enables
Filter Selection for WKUP_INT[15]
[30]
0 = delay filter 1 = digital filter(clock count)
Filtering width for WKUP_INT[15]
[29:24]
This value is valid if FLTSEL1 is1.
Filter Enable for WKUP_INT[14]
[23]
0 = disables 1 = enables
Filter Selection for WKUP_INT[14]
[22]
0 = delay filter 1 = digital filter(clock count)
Filtering width for WKUP_INT[14]
[21:16]
This value is valid if FLTSEL1 is1.
Filter Enable for WKUP_INT[13]
[15]
0 = disables 1 = enables
Filter Selection for WKUP_INT[13]
[14]
0 = delay filter 1 = digital filter(clock count)
Filtering width for WKUP_INT[13]
[13:8]
This value is valid if FLTSEL1 is1.
Filter Enable for WKUP_INT[12]
[7]
0 = disables 1 = enables
Filter Selection for WKUP_INT[12]
[6]
0 = delay filter 1 = digital filter(clock count)
Filtering width for WKUP_INT[12]
[5:0]
This value is valid if FLTSEL1 is1.
Description
PAD CONTRL
Reset
Value
0
0
000
0
0
000
0
0
000
0
0
000
2.2-91