Operation Pattern Of Primary Ip-Bs; When Synchronizing To The Sys-Id Specified By Office Data - NEC Univerge sv8500 Manual

Fp85-110 s7
Hide thumbs Also See for Univerge sv8500:
Table of Contents

Advertisement

3.1.3

Operation Pattern of PRIMARY IP-BS

(a)

When Synchronizing to the SYS-ID specified by office data

In this settings, the IP-BS starts up, synchronizing with the CS of specified ID. If not find any CS for the syn-
chronization, it will start running by itself. If the synchronizing connection in operation is down, it will start run-
ning by itself, searching for CS of the specified CS. Then, it will synchronize the one as soon ass the connection
is established.
Note:
When SYS-ID of existing CS to which PRIMARY BS synchronizes and SYS-ID of PRIMARY BS are the
same, (this is the case when using FCCS, or IPPAD) do not assign the SYS-ID of the CS for the PRIMARY
IP-B.
SYS-ID=A
Secondary
SUB-PRIMARY
SYNC
VOL.1-174
CHAPTER 3
INSTALLATION DESIGN
CSI
CS
SYNC
PRIMARY
SYNC
SYS-ID=B
Internal
PHE