Maintenance-Object Repair Procedures
f. Infrequent errors, at a rate which does not bring up an alarm, probably do
not affect service, unless there are customer complaints of no tones, or
incorrect tones which can not be explained in any other way. However, if
an alarm is raised because this error is being repeatedly logged, then the
circuit pack should be replaced. See
Circuit Pack'' on page
g. The system-parameters country-options administration requires a TN780
or TN2182 Tone-Clock or a TN2312 IPSI circuit pack, but the existing
Tone-Clock circuit does not provide the needed functionality. The Base
Tone Generation Set on page 1 or the custom tones beginning on page 2
of the system-parameters country options form may have values not
supported by the existing Tone-Clock.
This error (1281) indicates that the system parameters country-options
form has custom tones translated and that the alarmed tone board does
not support the customized tones. TN768 tone boards do not support any
customized tones. TN780 tone boards support up to 6 customized tones
using the following frequencies/levels only:
Silence
350Hz at 17.25 dB
425Hz at 4.0 dB
425Hz at 11.0 dB
425Hz at 17.25 dB
440Hz at 17.25 dB
350Hz+425Hz at 4.0 dB
350Hz+440Hz at 13.75 dB
480Hz at 17.25 dB
620Hz at 17.25 dB
440Hz+480Hz at 19.0 dB
8-1684
Issue 1 May 2002
''Replacing the IPSI or Tone-Clock
8-1666.
404Hz at 11.0 dB
404Hz at 16.0 dB
480Hz+620Hz at 24.0 dB
404Hz+425Hz at 11.0 dB
375Hz+425Hz at 15.0 dB
404Hz+450Hz at 11.0 dB
1000Hz at 0.0 dB
1000Hz at +3.0 dB
525Hz at 11.0 dB
1400Hz at 11.0 dB
555-233-143