Avaya S8700 Maintenance Manual page 2403

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

TONE-BD (Tone-Clock Circuit)
Table 8-651. Test #46 Clock Health Inquiry Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Internal system error.
Retry the command at 11-minute intervals up to 5 times.
none
FAIL
This Tone-Clock or IPSI circuit pack had an apparent loss of clock. One or
more of error types 2049, 2305, 3834, 3857, 3858, and 3872 will appear in the
error log. Correct the problem according to the appropriate error log entries.
Tone-Clock circuit pack – Once this test fails for a Tone-Clock circuit pack,
the only way to make it pass, and to retire the associated alarm, is to repair the
problem and to execute the set tone-clock UUC override command against
the indicated Tone-Clock circuit pack.
IPSI Tone -Clock – Once this test fails for an IPSI Tone-Clock, the only way to
make it pass (and to retire the associated alarm) is to repair the problem, to
execute the busy ipserver-interface command, and then issue the release
ipserver-interface command against the indicated IPSI circuit pack.
1
FAIL
This IPSI or Tone-Clock circuit pack is suspect of having a clock at the edge of
its specified frequency. A Tone-Clock circuit pack with this problem can cause
Expansion Interface circuit packs and SNI circuit packs to go out-of-frame or
report no neighbor conditions, thus causing EPNs, Expansion Archangel Links
(EALs), Remote Neighbor Links (RNLs), and/or Local Neighbor Links (LNLs) to
go down.
Replace the IPSI or Tone-Clock circuit pack identified in the error log. See
''Replacing the IPSI or Tone-Clock Circuit Pack'' on page
PASS
This IPSI or Tone-Clock circuit pack has not reported a loss of clock.
555-233-143
8-1666.
Continued on next page
Issue 1 May 2002
8-1681

Advertisement

Table of Contents
loading