Maintenance-Object Repair Procedures
Table 8-633. Test #7 Conference Circuit Test — Continued
Error
Test
Code
Result
Description / Recommendation
1004
ABORT
The port was seized by a user for a valid call.
1. Use the display port UUCSSpp command to determine the trunk
2. If the port status is idle, retry the command at 1-minute intervals up to 5
1018
ABORT
Test disabled via administration. This only applies to analog stations.
1. To enable test, set the Test field on the station administration screen for the
1020
ABORT
The test did not run due to a previously existing error on the specific port or
because of a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or circuit pack,
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2053
ABORT
At least one of the following errors is found on the DS1 circuit pack: 1281 –
Loss of signal,1793 – Blue alarm, 2049 – Red alarm, 2305 – Yellow alarm, or
1537 – Hyperactivity.
Look for the previous error types in the Hardware Error Log, and follow the
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the listed error types.
8-1630
Issue 1 May 2002
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. You must
wait until the port is idle before retesting.
times.
particular analog station being tested to "y." Use the change station
extension command.
and attempt to diagnose the previously existing error.
Continued on next page