Avaya S8700 Maintenance Manual page 2368

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-640. Test #33 Looparound and Conference Circuit Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test. This could
be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
7
ABORT
The conference circuit test was aborted.
1. Retry the command at 1-minute intervals up to 5 times.
129
ABORT
The 404-Hz reflective loop around test aborted. Response to the test request
was not received within the allowable time period.
131
The 1004-Hz reflective loop around test aborted. Response to the test
request was not received within the allowable time period.
133
The 2804-Hz reflective loop around test aborted. Response to the test
request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The trunk may be
busy with a valid call. Use the display trunk xx command to determine the
trunk group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait until
the port is idle before retesting.
1. If the port status is active, but the port is idle (no calls), then check the
2. If the port status is idle, then retry the command at 1-minute intervals up
1002
ABORT
The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized force.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 5
8-1646
Issue 1 May 2002
Error Log for Error Type 1025 (see Error Log table for description of this
error and required actions). The port may be locked up.
to 5 times.
repeat test at 1-minute intervals up to 5 times.
times.
Continued on next page
555-233-143

Advertisement

Table of Contents
loading

Table of Contents