TONE-PT (Tone Generator)
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the SAKI Reset test
for example, you may also clear errors generated from other tests in the testing
sequence.
Order of Investigation
SAKI Reset test (#53) (a)
Clock Health test (#46) (b)
Control Channel Loop-around test
(#52) (a)
Tone Generator Crosstalk test (#90)
Tone Generator Transmission test
(#40)
Tone Generator Audit/Update test
(#41)
TDM bus Clock Circuit Status Inquiry
test (#148) (c)
TDM Bus Clock Slip Inquiry test (#149)
(c)(e)
TDM bus Clock PPM Inquiry test
(#150) (c)
TDM bus Clock Parameter Update test
(#151) (c)
Board Type Check test (#574) (c)
Standby Reference Health Check test
(#651) (c, d)
1.
D = Destructive; ND = Nondestructive
Notes:
a. See
''XXX-BD (Common Port Circuit Pack)''
b. See
''TONE-BD (Tone-Clock Circuit)''
c. See
''TDM-CLK (TDM Bus Clock)''
d. This test only runs on the standby IPSI or Tone-Clock circuit in an EPN
with more than one IPSI or Tone-Clock circuit pack (high- or
critical-reliability system). The circuit pack must be a TN780 code with
firmware revision 2 or above.
e. Test #149 does not run on the TN2182 or TN2312.
555-233-143
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
for descriptions of these tests.
for descriptions of these tests.
for descriptions of these tests.
Issue 1 May 2002
Reset Board
1
Sequence
D/ND
D
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
8-1685