Avaya S8700 Maintenance Manual page 2348

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-632. Test #6 NPE Crosstalk Test
Error
Test
Code
Result
Description / Recommendation
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test were not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the trunk
2. If the port status is active but the port is idle (no calls), check the error log
3. If the port status is idle, retry the command at 1-minute intervals up to 5
1001
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions, or it may have time slots out of service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic and
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present or some of the tone
detectors may be out of service. Issue the list measurements tone-receiver
command to display basic information about the system's tone receivers.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5 times.
1004
ABORT
The port was seized by a user for a valid call.
1. Use the display port UUCSSpp command to determine the trunk
2. If the port status is idle, retry the command at 1-minute intervals up to 5
8-1626
Issue 1 May 2002
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. You must
wait until the port is idle before retesting.
for error type 1025 (see the error log table for a description of this error and
required actions). The port may be locked up.
times.
the port status is idle, retry the command at 1-minute intervals up to 5
times.
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. You must
wait until the port is idle before retesting.
times.
Continued on next page
555-233-143

Advertisement

Table of Contents
loading

Table of Contents