TONE-BD (Tone-Clock Circuit)
Error Log Entries and Test to Clear Values
Table 8-648. Tone-Clock Circuit Pack Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1 (a)
0
Circuit pack removed or
SAKI Sanity test (#53)
18 (b)
0
busyout tone-clock PC WARNING OFF
23 (c)
0
None
125 (d)
None
126 (e)
None
257 (f)
65535 Control Channel test
(#52)
257 (f)
Any
None
513 (g)
Any
None
769 (h)
4358
None
1025 (i)
4363
NPE Audit test (50)
1538 (j)
Any
None
2049 (k)
0
Clock Health Inquiry test
(#46)
2305 (k)
0
Clock Health Inquiry test
(#46)
2561 (l)
Any
None
3329
0
None
(m)
3840 (n)
Any
None
3848 (o)
0
Clock Health Inquiry test
(#46)
3856 (p)
3857,
NONE
3858 (q)
3872 (r)
0
None
3999 (s)
Any
None
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set options
command.
3.
For a TN2312 IPSI-supported port network, use the command set ipserver-interface.
555-233-143
Alarm
On/Off
Level
Board
Test to Clear Value
Any
Any
test tone-clock PC sh
MINOR
ON
release tone-clock PC
WARNING OFF
MINOR
ON
MINOR
ON
MINOR
ON
test tone-clock PC r 20
test tone-clock PC sh
MINOR
ON
MAJOR
ON
set tone-clock UC override
MAJOR
ON
set tone-clock UC override
MAJOR
ON
MINOR/
OFF
set tone-clock UC override
WARNING
2
set tone-clock UC override
MAJOR
ON
set tone-clock UC override
MAJOR
ON
busyout/release
ipserver-interface
set tone-clock UC override