TIME-DAY (Time of Day)

MO's Name (in
Alarm Log)
TIME-DAY
The time of day contains the current year, month, day of the week, day of the
month, hour, minute, and second. The Time of Day MO is responsible for
monitoring the time-of-day clock and raising an alarm if the time-of-day clock is
not set or cannot be read by the software. If the time-of-day clock is not set or
cannot be read by the software, many features such as Time-of-Day Routing,
CDR, ISDN Call-by-Call, duplication, and so on will be either inoperative or
incorrect. The time-of-day clock should be set using the set time command
whenever the system is initially powered up.
The time-of-day clock can be read with the display time command and set via the
set time command. The time-of-day clock has a backup battery to save the time
of day during power failures.
Error Log Entries and Test to Clear Values
Table 8-645. Time-of-Day Error Log Entries
Error
Aux
Type
Data
Associated Test
0
0
Any
1
247
0
none
1.
This error indicates that software cannot read the time-of-day clock. During this condition, every time stamp
in Alarm Log entries, Hardware Error Log entries, and Software Error Log entries is potentially inaccurate.
In addition, any features that are sensitive to the time of day (such as SMDR, Time-of-Day Routing, ISDN
Call-by-Call) will not function correctly.
To resolve the alarm, do the following:
1. Use the set time command to set the time of day.
2. Use the display time command to display the time of day. If the time of
day is displayed correctly, wait 15 minutes and verify that the alarm is
retired.
8-1658
Issue 1 May 2002
Alarm
Initial SAT Command
Level
To Run
MINOR
set time
Alarm
Level
Any
MINOR
Full Name of MO
Time of Day
On/Off
Board
Test to Clear Value
Any
display time
OFF
set time