2.4.4
Data Programming
SP-PHI is embedded in, and controlled by MPH. For the use of MPH, it is required to make Internal
Note:
PHE function valid. So Internal PHE data assignment is also necessary for the use of SP-PHI. About the
procedure for Internal PHE data assignment, refer to
STEP 1: ASYDL
Assign SP Implementation as valid.
SYS 1, Index 885, Bit 7= 1 (SP Implementation is valid.)
STEP 2: ALIDL
Specify the LENS (five digits) as the accommodated location of MPH and SP-PHI.
PH LENS:
Specify an even-numbered Group No. other than those 24 through 31.
PH TYPE:
Select "MPH" in the combo box.
MPH-ID:
Identification number of MPH [1-4095]
- Single CPU: MPH-ID = 1 (Fixed)
- Dual CPU: MPH-ID = 1 and 2 (Fixed)
Assign MPH-ID=1 for CPU #0 and MPH-ID=2 for CPU #1.
Note:
PH TYPE:
Select "PHI" in the combo box.
PH LENS:
Line Equipment Number of SP-PHI accommodated slot
Do not assign the same LENS as that of MPH.
REGMAX:
Capacity of registration [1-4095] (default: 256)
MGC PORT: Controlling Signaling Port Number for TP [1-65535] (default: 64105)
TERM PORT: Controlling Signaling Port Number for SP-PHI [1-65535] (default: 64010)
One Group (8 ports) is used for MPH/SP-PHI accommodated location respectively.
Note 1:
LENS = two-digit Module Group Number + one-digit Unit Number + two-digit Group Number
The LENS can be allocated on either a Virtual PIR or a Physical PIR.
Note 2:
The figure below is an example to show MPH/SP-PHI accommodated location. In this example, "01308"
is specified to LENS and the Group colored blue is the accommodated location corresponding to the
LENS.