2.5

How to Assign Virtual PIR

2.5.1
General
Virtual PIR is a non-physical Port Interface Rack. Some PHs must be accommodated in Virtual PIR. Virtual PIR
can also be used for IP terminal, the Subline of Dterm, and voice channel for CCIS over IP.
The existing Virtual PIR data cannot be deleted while the System is in on-line mode (The existing Virtual
Note:
PIR data must be deleted during the off-line mode). After deleting the Virtual PIR data, the System must
be initialized.
2.5.2
Hardware Required
None
2.5.3
Installation Procedure
None
CHAPTER 2
Virtual PIR Available MGs
IMG0
IMG1
MG01
MG03
(PIR 3)
(PIR 3)
(PIR 2)
(PIR 2)
MG00
MG02
(PIR 1)
(PIR 1)
(PIR 0)
(PIR 0)
VOL.1-102
IP-RELATED BASIC FEATURE PROGRAMMING
IMG2
MG05
MG07
(PIR 3)
(PIR 2)
MG04
MG06
(PIR 1)
(PIR 0)
IMG3
(PIR 3)
(PIR 2)
(PIR 1)
(PIR 0)