NEC Univerge sv8500 Manual page 201

Fp85-110 s7
Hide thumbs Also See for Univerge sv8500:
Table of Contents

Advertisement

STEP 2: ALOCL
Assign the Location-ID data on a network basis.
STEP 3: AIVCL
Assign adequate PAD value by specifying two Location-IDs. The total PAD value that is obtained by add-
ing the PAD value specified in this STEP and PAD value specified in STEP 1 (ASYD, SYS 1, Index 4,
Bit 5) is applied to both SENDING and RECEIVING sides. In the following example, 2 dB is assigned
by AIVCL between Location ID=1 and Location ID=2 for DtermIP.
The total PAD value (1) ASYD, SYS1, Index 4, Bit 5 + (2) AIVCL is applied.
Data Programming by AIVCL
Location-A = Location ID 0
Location-B = Location ID 1
PAD = 2 dB
CHAPTER 2
PAD Control by Location ID - AIVCL
Location ID=0
Telephony Server
DtermIP
2 dB
11 dB
<applied PAD Value>
SND = 0+2 = 2 dB
RCV = 9+2 = 11 dB
VOL.1-141
IP-RELATED BASIC FEATURE PROGRAMMING
IP Network
2 dB
11 dB
<applied PAD Value>
SND = 0+2 = 2 dB
RCV = 9+2 = 11 dB
Location ID=1
DtermIP
DtermIP

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents