3Com Router Command Reference Guide — V1.00
1.1.24 interface dialer
Syntax
interface dialer number
undo interface dialer number
View
All views
Parameter
number: Interface number in the range of 0 to 4294967295.
Description
Using the interface dialer command, you can create a dialer circular group in the
Circular DCC configuration or configure a dialer interface in the Resource-Shared
DCC configuration. Using the undo interface dialer command, you can cancel the
existing setting.
By default, no dialer interface is defined.
In Resource-Shared DCC, any dialer interface can use the services provided by
multiple physical interfaces, and individual physical interfaces can provide services for
multiple dialer interfaces at the same time. Therefore, authentication must be
configured on these physical interfaces, so as to use the user name of a dial-in party
to locate the corresponding dialer interface for the call. In this mode, physical
interfaces and dialer interfaces are dynamically bound. Furthermore, a dialer interface
can only call a destination address, which will be specified in the dialer number
command.
The physical interfaces in Circular DCC and Resource-Shared DCC do not use
individual network addresses. Instead, they use the addresses of the corresponding
dialer interfaces.
Example
# Define a dialer interface dialer 1.
[3Com] interface dialer 1