Radius Timer Quiet; Radius Timer Realtime-Accounting - 3Com 3C13618 Command Reference Manual

3com 3c13618: reference guide
Table of Contents

Advertisement

2.1.21 radius timer quiet

Syntax
radius timer quiet minutes
undo radius timer quiet
View
System view
Parameter
minutes: Recovery time after the server fails, in minute, ranging 1 to 255. The fault
value is 5 minutes.
Description
Using the radius timer quiet command, you can configure the resuming time after
the RADIUS server fails. Using the undo radius timer quiet command, you can
restore the default value.
When the RADIUS server fails (like the line between NAS and RADIUS has a
loosened screw or the RADIUS process fails to function), the system will set its status
as down. After the resuming time configured above, the system will set its status as
up. If the server in service now fails, the system will auto-check whether or not the
original server can be put into service.
Example
# Configure 10 minutes as the resuming time after the failure of the RADIUS server.
[3Com]radius timer quiet 10

2.1.22 radius timer realtime-accounting

Syntax
radius timer realtime-accounting minutes
undo radius timer realtime-accounting
View
System view
Security
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3c136123c136133c13616

Table of Contents