N x 56 kbps). The interface has the same logic feature as that of a synchronous
serial interface; therefore, it can be regarded as a synchronous serial interface for
further configuration.
For related commands, see t1 unframed.
Example
# Bind a 128Kbps serial port on the first T1 channel on T3 0 interface.
[3Com-T3-0]t1 1 channel-set 1 timeslot-list 1,2

3.7.9 t1 set clock

Syntax
t1 line-number set clock { master | slave }
undo t1 line-number set clock
View
CT3 interface view
Parameter
line-number: T1 channel number in the range of 1 to 28.
master: Uses the internal clock.
slave: Uses the line clock.
Description
Using the t1 set clock command, you can configure the clock mode for the T1
channels on the CT3 interface. Using the undo t1 set clock command, you can
restore the default setting.
By default, the clock mode is slave.
When CT3 interface is channelized, each T1 channel can separately set clock.
Example
# Set the clock mode for the first T1 channel on T3 interface to line clock.
[3Com-T3-0]t1 1 set clock slave