E1 Set Clock - 3Com 3C13618 Command Reference Manual

3com 3c13618: reference guide
Table of Contents

Advertisement

Description
Using the e1 channel-set command, you can bind the time slots on E1 channels.
Using the undo e1 channel-set command, you can disable the time slot binding.
By default, no channel-set is bound.
CE3 interface supports 64Kbps for one channel. Thus, a maximum of 31 channels
can be bound on each E1 line.
When E1 channel works in Channelized E1 mode (framed mode), timeslot binding
can be performed on it. The system will automatically create a serial interface whose
number is serial number / line-number:set-number and whose rate is N x 64 kbps.
The interface has the same logic feature as that of a synchronous serial interface;
therefore, it can be regarded as a synchronous serial interface for further
configuration.
For related commands, see e1 unframed.
Example
# Bind a 128Kbps serial port on the first E1 channel on E3 0 interface.
[3Com-E3-0]e1 1 channel-set 1 timeslot-list 1,2

3.6.5 e1 set clock

Syntax
e1 line-number set clock { master | slave }
undo e1 line-number set clock
View
CE3 interface view
Parameter
line-number: E1 channel number in the range of 1 to 16.
master: Uses the internal clock.
slave: Uses the line clock.
Interface Management
63

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3C13618 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

3c136123c136133c13616

Table of Contents