Sdlc Window - 3Com 3C13618 Command Reference Manual

3com 3c13618: reference guide
Table of Contents

Advertisement

Description
Using the sdlc timer poll command, you can configure the time between two poll
packets. Using the undo sdlc timer poll command, you can restore the time
between two poll packets.
SDLC polling mechanism is adopted to query the nodes periodically. SDLC polling
time interval refers to the time interval between two node querying operations
initiated by the the SDLC primary station.
Example
None

6.1.42 sdlc window

Syntax
sdlc window length
undo sdlc window
View
Synchronous interface view
Parameter
length: Length of the local acknowledgement window, ranging from 1 to 7. By default,
the length of the local acknowledgement window of SDLC is 7
Description
Using the sdlc window command, you can configure the size of the SDLC local
window, that is, the max number of frames that can be sent before receiving the
response frames. Using the undo sdlc window command, you can restore the size
of the SDLC local window to the default value.
Window mechanism is adopted when SDLC is sending frames. With the mechanism,
SDLC does not expect that the receiving party respond to each frame, instead, it will
wait for the response after sending the window of frames.
Example
None