Example
# Bind the timeslots 1, 2, 10-15 and 18 on the /PRI interface as channel-set 0.
[3Com-T1-0]channel-set 0 timeslot-list 1,2,10-15,18

3.3.3 clock (/PRI Interface)

Syntax
clock { master | slave }
undo clock
View
/PRI interface view
Parameter
master: Use the internal clock mode.
slave: Use the line clock mode.
Description
Using the clock command, you can configure the clock mode on the /PRI interface.
Using the undo clock command, you can restore the default clock mode on the
interface.
By default, the interface uses the slave clock mode.
When the /PRI interface operates as DCE, you should choose the internal clock,
namely, master clock mode. When it operates as DTE, you should choose the line
clock, namely, slave clock mode.
Example
# Set the clock on the /PRI interface to operate in DCE mode.
[3Com-T1-0]clock master

3.3.4 code (/PRI Interface)

Syntax
code { ami | b8zs }
undo code
Interface Management