Llc2 Timer Poll - 3Com 3C13618 Command Reference Manual

3com 3c13618: reference guide
Table of Contents

Advertisement

3Com Router Command Reference Guide — V1.00
Parameter
mseconds: The time interval to query the station which is in the LLC2 BUSY status
for the second time. The value range is 1~6000ms while the default value is 300ms.
Description
Using the llc2 timer busy command, you can configure the waiting time while other
LLC2 station is in busy state. Using the undo llc2 timer busy command, you can
restore the time interval to the default value..
In the case that LLC2 queries the station status, it will wait and query again if the
station status is BUSY.
Example
None

6.1.24 llc2 timer poll

Syntax
llc2 timer poll mseconds
undo llc2 timer poll
View
Ethernet interface view
Parameter
mseconds: The P/F wait time of LLC2. The value range is 1~60000ms and the
default value is 5000ms.
Description
Using the llc2 timer poll command, you can configure the P/F wait time of LLC2.
Using the undo llc2 timer poll command, you can restore the P/F wait time of LLC2
to the default value.
After LLC2 sends a P frame, if it does not receive a F frame from peer, LLC2 will
retransmit the P frame.
Example
None