1.4 A: Initialization Parameters

1.4

A: Initialization Parameters

A1: Initialization

No.
Name
(Hex.)
A1-00
Language Selection
(0100)
RUN
A1-01
Access Level Selection
(0101)
RUN
A1-02
Control Method Selection
(0102)
A1-03
Initialize Parameters
(0103)
A1-04
Password
(0104)
A1-05
Password Setting
(0105)
A1-06
Application Preset
(0127)
A1-07
DriveWorksEZ Function
Selection
(0128)
22
V/f
OLV/PM
OLV/PM EZOLV
Sets the language for the HOA keypad.
Note:
When you use A1-03 [Initialize Parameters] to initialize the drive, the drive will not
reset this parameter.
0 : English
1 : Japanese
2 : German
3 : French
4 : Italian
5 : Spanish
6 : Portuguese
V/f
OLV/PM EZOLV
OLV/PM
Sets user access to parameters. The access level controls which parameters the keypad will
display and which parameters the user can set.
0 : Operation Only
1 : User Parameters
2 : Advanced Level
3 : Expert Level
4 : Lock Parameters
V/f
OLV/PM EZOLV
OLV/PM
Sets the control method for the drive application and the motor.
0 : V/f Control
5 : PM Open Loop Vector
8 : EZ Vector Control
V/f
OLV/PM
OLV/PM EZOLV
Sets parameters to default values.
0 : No Initialization
1110 : User Initialization
2220 : 2-Wire Initialization
3330 : 3-Wire Initialization
3410 : HVAC Initialization
V/f
OLV/PM
OLV/PM EZOLV
Entry point for the password set in A1-05 [Password Setting]. The user can view the
settings of parameters that are locked without entering the password. Enter the correct
password in this parameter to change parameter settings.
V/f
OLV/PM EZOLV
OLV/PM
Sets a password to lock parameters and prevent changes to parameter settings. Enter the
correct password in A1-04 [Password] to unlock parameters and accept changes.
V/f
OLV/PM
OLV/PM EZOLV
Sets the drive to operate in selected application conditions.
0 : No Preset Selected
1 : General Purpose Fan
2 : Fan w/ PID Control
3 : Return Fan w/ PID Control
4 : Cooling Tower Fan
5 : Cooling Tower Fan w/ PID
6 : Secondary Pump
7 : Pump w/ PID Control
8 : Pump Network Multiplex
V/f
OLV/PM EZOLV
OLV/PM
Sets the drive to operate with DriveWorksEZ.
0 : DWEZ Disabled
1 : DWEZ Enabled
2 : Enabled/Disabled wDigital Input
Description
YASKAWA TOEPYAIHV6002A HV600 Drive Programming
Default
Ref.
(Range)
0
161
(0 - 6)
2
161
(0 - 4)
0
162
(0 - 8)
0
163
(0 - 3410)
0000
164
(0000 - 9999)
0000
165
(0000 - 9999)
0
165
(0 - 8)
0
175
(0 - 2)

Hide quick links: