1.10 H: Terminal Functions
Setting Value
Function
160
!Internal Cooling Fan
Failure
161
!Pole Position Detection
Complete
162
!Modbus Reg 1 Status
Satisfied
163
!Modbus Reg 2 Status
Satisfied
169
!External Power 24V
Supply
16A
!Data Logger Error
171
!Low PI2 Control
Feedback Level
172
!High PI2 Control
Feedback Level
189
!Output Current Lim
190
!DWEZ Digital Outputs 1
191
!DWEZ Digital Outputs 2
192
!DWEZ Digital Outputs 3
194
!Loss of Prime
195
!Thermostat Fault
196
!High Feedback
197
!Low Feedback
19E
!Low PI Auxiliary
Control Level
19F
!High PI Auxiliary
Control Level
1A9
!RELAY Operator
Control
1AA
!Utility Delay
1AB
!Thrust Mode
1AC
!Setpoint Not Maintained
68
V/f
OLV/PM EZOLV
OLV/PM
The terminal deactivates when the drive detects a cooling fan failure in the drive.
V/f
OLV/PM
OLV/PM EZOLV
The terminal deactivates when drive receives a Run command and the drive detects the motor magnetic pole position
of the PM motor.
V/f
OLV/PM
OLV/PM EZOLV
The terminal deactivates when the bit specified by H2-08 [Modbus Register 1 Bit Select] for the MEMOBUS register
address set with H2-07 [Modbus Register 1 Address Select] activates.
V/f
OLV/PM
OLV/PM EZOLV
The terminal deactivates when the bit specified by H2-10 [Modbus Register 2 Bit Select] for the MEMOBUS register
address set with H2-09 [Modbus Register 2 Address Select] activates.
V/f
OLV/PM EZOLV
OLV/PM
The terminal deactivates when there is an external 24V power supply between terminals PS-AC.
ON : An external 24V power supply does not supply power.
OFF : An external 24V power supply supplies power.
V/f
OLV/PM
OLV/PM EZOLV
The terminal deactivates when the drive detects LoG [Com Error / Abnormal SD card].
V/f
OLV/PM
OLV/PM EZOLV
The terminal deactivates when the PI2 Control Feedback Level is less than S3-13 [PI2 Control Low Feedback Lvl].
V/f
OLV/PM EZOLV
OLV/PM
The terminal deactivates when the PI2 Control Feedback Level is more than S3-15 [PI2 Control High Feedback Lvl].
V/f
OLV/PM
OLV/PM EZOLV
The terminal deactivates when the output current limit is limiting the drive output speed.
V/f
OLV/PM EZOLV
OLV/PM
Sets the digital output 1 to use in DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
V/f
OLV/PM EZOLV
OLV/PM
Sets the digital output 2 to use in DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
V/f
OLV/PM EZOLV
OLV/PM
Sets the digital output 3 to use in DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
V/f
OLV/PM
OLV/PM EZOLV
The terminal deactivates when the drive is in an LOP [Loss of Prime] condition.
V/f
OLV/PM EZOLV
OLV/PM
The terminal deactivates when the terminal set for H1-xx = 88 [MFDI Function Selection = Thermostat Fault] is
active.
V/f
OLV/PM EZOLV
OLV/PM
The terminal deactivates when the drive is in a High Feedback Condition as specified by Y1-11 [High Feedback Level]
and Y1-12 [High Feedback Lvl Fault Dly Time] and when the drive detects an HFB [High Feedback Sensed] fault or
an HIFB [High Feedback Sensed] alarm.
V/f
OLV/PM
OLV/PM EZOLV
The terminal deactivates when the drive is in a Low Feedback Condition as specified by Y1-08 [Low Feedback Level]
and Y1-09 [Low Feedback Lvl Fault Dly Time] and when the drive detects an LFB [Low Feedback Sensed] fault or an
LOFB [High Feedback Sensed] alarm.
V/f
OLV/PM EZOLV
OLV/PM
The terminal deactivates when the PI Aux Feedback Level is less than YF-09 [PI Aux Control Low Level Detect] or if
the drive detects an LOAUX [Low PI Aux Feedback Level] fault.
V/f
OLV/PM
OLV/PM EZOLV
The terminal deactivates when the PI Aux Feedback Level is more than YF-12 [PI Aux Control High Level Detect] or
if the drive detects an HIAUX [High PI Aux Feedback Level] fault.
V/f
OLV/PM EZOLV
OLV/PM
The terminal changes to OFF or ON when you push the RELAY (
to turn it OFF. When the terminal is OFF, push
V/f
OLV/PM EZOLV
OLV/PM
The terminal deactivates when the drive is stopped and is waiting for the timer set in Y4-17 [Utility Start Delay] to
expire.
V/f
OLV/PM EZOLV
OLV/PM
The terminal deactivates when the output frequency is between 0.0 Hz and the value set in Y4-12 [Thrust Frequency]
and the Thrust Bearing function is active.
V/f
OLV/PM EZOLV
OLV/PM
The terminal deactivates when the drive detects NMS [Setpoint Not Met] condition.
Description
) button. When the terminal is ON, push
to turn in ON.
YASKAWA TOEPYAIHV6002A HV600 Drive Programming
Ref.
324
324
324
324
324
324
324
324
324
324
324
324
324
324
324
324
324
324
324
324
324
324

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF