H7: Virtual Mfio Selection - YASKAWA HV600 Manual

Ac drive for hvac fan and pump applications
Hide thumbs Also See for HV600:
Table of Contents

Advertisement

H5-27: Function 5A Register 3 Selection
No.
Name
(Hex.)
H5-27
Function 5A Register 3
Selection
(158B)
RUN
H5-28: Function 5A Register 4 Selection
No.
Name
(Hex.)
H5-28
Function 5A Register 4
Selection
(158C)
RUN
H5-33: Power-up CALL Alarm
No.
Name
(Hex.)
H5-33
Power-up CALL Alarm
(3FB3)
0 : Disabled
1 : Enabled
H5-34: Comm Error (CE) Go-To-Frequency
No.
Name
(Hex.)
H5-34
Comm Error (CE) Go-To-
Frequency
(3FB4)
RUN
H5-35: Comm Error (CE) Go-To-Timeout
No.
Name
(Hex.)
H5-35
Comm Error (CE) Go-To-
Timeout
(3FB5)
RUN
Note:
Set this parameter to 0 s to disable the time-out.
H5-36: CE Fault Restart Select
No.
Name
(Hex.)
H5-36
CE Fault Restart Select
(3FB6)
0 : No Retry
1 : Retry
The drive will restart after the L5-04 [Interval Method Restart Time] timer is expired.

H7: Virtual MFIO Selection

Use the virtual I/O function for these applications:
• Input the result of the output from the MFDO terminal to the MFDI terminal without external wiring.
• Input the result of the output from the MFAO terminal to the MFAI terminal without external wiring.
YASKAWA TOEPYAIHV6002A HV600 Drive Programming
V/f
OLV/PM EZOLV
OLV/PM
Returns the contents of the specified MEMOBUS/Modbus communications register when responding
to the master device.
V/f
OLV/PM
OLV/PM EZOLV
Returns the contents of the specified MEMOBUS/Modbus communications register when responding
to the master device.
V/f
OLV/PM
OLV/PM EZOLV
Enables and disables CALL [Serial Comm Transmission Error] alarm detection.
V/f
OLV/PM EZOLV
OLV/PM
Sets the speed at which the drive will run when H5-04 = 4 [Communication Error Stop Method =
Run at H5-34] and there is a CE.
V/f
OLV/PM EZOLV
OLV/PM
When H5-04 = 4 [Communication Error Stop Method = Run at H5-34] and a CE is present, the drive
will run at the H5-34 [Comm Error (CE) Go-To-Frequency] speed for this length of time before it
triggers a CE fault.
V/f
OLV/PM EZOLV
OLV/PM
Sets the drive to restart (L5-01 [Number of Auto-Restart Attempts]) after a CE fault.
Description
Description
Description
Description
Description
Description
2.8 H: Terminal Functions
Default
(Range)
0042H (U1-03)
(0000H - FFFFH)
Default
(Range)
0049H (U1-10)
(0000H - FFFFH)
Default
(Range)
1
(0, 1)
Default
(Range)
0.0 Hz
(0.0 - 400.0 Hz)
Default
(Range)
0 s
(0 - 6000 s)
Default
(Range)
0
(0, 1)
345
2

Hide quick links: