Note:
The drive can write data to the keypad a maximum of 100,000 times. If you write data to the keypad more than 100,000 times, you must
replace the keypad.
0 : Every 10 minutes
1 : Every 30 minutes
2 : Every 60 minutes
3 : Every 12 hours

o4: Maintenance Mon Settings

o4 parameters set the expected service life to help you know when to replace parts. The drive will show an alarm to
tell you when the replacement part interval is near.
o4-01: Elapsed Operating Time Setting
No.
Name
(Hex.)
o4-01
Elapsed Operating Time
Setting
(050B)
When you select o4-01 on the keypad, it will show the current value of U4-01 in units of 10 hours (h). When you
change the setting of o4-01 through the monitor, the U4-01 count starts again as specified by the setting of o4-01.
Note:
Set this parameter in 10-hour (h) units. When o4-01 = 30, U4-01 [Cumulative Ope Time] = 300 h.
o4-02: Elapsed Operating Time Selection
No.
Name
(Hex.)
o4-02
Elapsed Operating Time
Selection
(050C)
0 : U4-01 Shows Total Power-up Time
Counts the time from when you energize drive to when you de-energize the drive.
1 : U4-01 Shows Total RUN Time
Counts the time that the drive outputs voltage.
o4-03: Fan Operation Time Setting
No.
Name
(Hex.)
o4-03
Fan Operation Time Setting
(050E)
Use monitor U4-03 [Cooling Fan Ope Time] to view the total operation time of the cooling fan. When you replace a
cooling fan, set o4-03 = 0 to reset U4-03. Select o4-03 on the keypad to show the current value of U4-03 in 10-hour
(h) units. If you use the monitor to change o4-03, the recount of U4-03 starts with the o4-03 setting.
Note:
The drive sets o4-03 in 10-hour (h) units. When o4-03 = 30, U4-03 [Cooling Fan Ope Time] will show "300 h".
o4-05: Capacitor Maintenance Setting
No.
Name
(Hex.)
o4-05
Capacitor Maintenance
Setting
(051D)
When you replace a drive, set o4-05 = 0 to reset U4-05. When the o4-05 setting changes, the count of U4-05 starts
again as specified by the setting of o4-05. After you complete the configuration, o4-05 automatically resets to 0.
YASKAWA TOEPYAIHV6002A HV600 Drive Programming
V/f
OLV/PM EZOLV
OLV/PM
Sets the initial value of the cumulative drive operation time in 10-hour units.
V/f
OLV/PM EZOLV
OLV/PM
Sets the condition that counts the cumulative operation time.
V/f
OLV/PM EZOLV
OLV/PM
Sets the value from which to start the cumulative drive cooling fan operation time in 10-hour units.
V/f
OLV/PM EZOLV
OLV/PM
Sets the U4-05 [CapacitorMaintenance] monitor value.
2.11 o: Keypad-Related Settings
Description
Description
Description
Description
Default
(Range)
0 h
(0 - 9999 h)
Default
(Range)
1
(0, 1)
Default
(Range)
0 h
(0 - 9999 h)
Default
(Range)
2
0%
(0 - 150%)
421