YASKAWA HV600 Manual page 147

Ac drive for hvac fan and pump applications
Hide thumbs Also See for HV600:
Table of Contents

Advertisement

1.20 Parameters that Change from the Default Settings with A1-02 [Control Method Selection]
*3
The setting range varies depending on the setting of E5-01 [PM Motor Code Selection] when A1-02 = 5 [Control Method Selection = PM
Open Loop Vector].
*4
The default setting changes when the drive model and E1-03 [V/f Pattern Selection] change.
*5
This is the value for 208 V class drives. Double the value for 480 V class drives.
*6
The default value changes when the drive model changes.
A1-02 = 5 and 8 [OLV/PM and EZOLV]
No.
b2-13
Short Circuit Brake Time @ Stop
b3-02
SpeedSearch Deactivation Current
b3-08
Speed Estimation ACR P Gain
b3-09
Speed Estimation ACR I Time
b3-14
Bi-directional Speed Search
b3-24
Speed Search Method Selection
b8-19
E-Save Search Injection Freq
C2-01
S-Curve Time @ Start of Accel
C3-02
Slip Compensation Delay Time
C3-22
Motor 2 Slip Comp Delay Time
C4-01
Torque Compensation Gain
C4-02
Torque Compensation Delay Time
C5-01
ASR Proportional Gain 1
C5-02
ASR Integral Time 1
C5-03
ASR Proportional Gain 2
C5-04
ASR Integral Time 2
C5-06
ASR Delay Time
C6-02
Carrier Frequency Selection
E1-04
Maximum Output Frequency
E1-05
Maximum Output Voltage
E1-06
Base Frequency
E1-07
Mid Point A Frequency
E1-08
Mid Point A Voltage
E1-09
Minimum Output Frequency
E1-10
Minimum Output Voltage
E1-11
Mid Point B Frequency
E1-12
Mid Point B Voltage
E1-13
Base Voltage
L1-01
Motor Overload (oL1) Protection
L2-31
KEB Start Voltage Offset Level
L3-05
Stall Prevention during RUN
L3-20
DC Bus Voltage Adjustment Gain
L8-38
Carrier Frequency Reduction
n8-51
Pull-in Current @ Acceleration
o1-03
Frequency Display Unit Selection
*1
Enabled only when E9-01 = 1 [Motor Type Selection = Permanent Magnet (PM)]
YASKAWA TOEPYAIHV6002A HV600 Drive Programming
Name
Range
0.00 - 25.50
0 - 200
0.00 - 6.00
0.0 - 1000.0
0 - 1
1 - 2
10 - 300
0.00 - 10.00
0 - 10000
0 - 10000
0.00 - 2.50
0 - 60000
0.00 - 300.00
0.000 - 60.000
0.00 - 300.00
0.000 - 60.000
0.000 - 0.500
1 - F
40.0 - 400.0
*5
0.0 - 255.0
0.0 - 400.0
0.0 - 400.0
*5
0.0 - 255.0
0.0 - 400.0
*5
0.0 - 255.0
0.0 - 400.0
*5
0.0 - 255.0
*5
0.0 - 255.0
0 - 4
*5
0 - 100
0 - 3
0.00 - 5.00
0 - 3
0 - 200
0 - 3
Control Method (A1-02 Setting)
Unit
OLV/PM (5)
0.01 s
0.50
1%
-
0.01
0.30
0.1 ms
2.0
1
-
1
-
1 Hz
-
0.01 s
1.00
1 ms
-
1 ms
-
0.01
0.00
1 ms
100
0.01
-
0.001 s
-
0.01
-
0.001 s
-
0.001 s
-
*2
1
2
0.1 Hz
Determined by E5-01
0.1 V
Determined by E5-01
0.1 Hz
Determined by E5-01
0.1 Hz
-
0.1 V
-
0.1 Hz
Determined by E5-01
0.1 V
-
0.1 Hz
-
0.1 V
-
0.1 V
-
1
4
1 V
50
1
2
0.01
0.65
1
-
1%
50
1
2
EZOLV (8)
*1
0.00
-
*2
0.60
10.0
0
*3
1
20
1.00
200
-
0.00
200
10.00
0.500
10.00
0.500
0.004
*2
2
-
-
-
-
-
-
-
-
-
-
*6
1
50
3
1
0.65
-
80
*7
0
147

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents