2.11 o: Keypad-Related Settings
■
o1-47: Trend Plot 1 Scale Minimum Value
No.
Name
(Hex.)
o1-47
Trend Plot 1 Scale Minimum
Value
(11C7)
RUN
■
o1-48: Trend Plot 1 Scale Maximum Value
No.
Name
(Hex.)
o1-48
Trend Plot 1 Scale
Maximum Value
(11C8)
RUN
■
o1-49: Trend Plot 2 Scale Minimum Value
No.
Name
(Hex.)
o1-49
Trend Plot 2 Scale Minimum
Value
(11C9)
RUN
■
o1-50: Trend Plot 2 Scale Maximum Value
No.
Name
(Hex.)
o1-50
Trend Plot 2 Scale
Maximum Value
(11CA)
RUN
■
o1-51: Trend Plot Time Scale Setting
No.
Name
(Hex.)
o1-51
Trend Plot Time Scale
Setting
(11CB)
RUN
■
o1-55: Analog Gauge Area Selection
No.
Name
(Hex.)
o1-55
Analog Gauge Area
Selection
(11EE)
RUN
0 : +/- Area ( - o1-56 ~ o1-56 )
1 : + Area ( 0 ~ o1-56 )
■
o1-56: Analog Gauge Area Setting
No.
Name
(Hex.)
o1-56
Analog Gauge Area Setting
(11EF)
RUN
414
V/f
OLV/PM
OLV/PM EZOLV
Sets the horizontal axis minimum value used to display the monitor set in o1-24 [Custom Monitor 1]
as a trend plot. This parameter is only available on an HOA keypad.
V/f
OLV/PM
OLV/PM EZOLV
Sets the horizontal axis maximum value used to display the monitor set in o1-24 [Custom Monitor 1]
as a trend plot. This parameter is only available on an HOA keypad.
V/f
OLV/PM
OLV/PM EZOLV
Sets the horizontal axis minimum value used to display the monitor set in o1-25 [Custom Monitor 2]
as a trend plot. This parameter is only available on an HOA keypad.
V/f
OLV/PM
OLV/PM EZOLV
Sets the horizontal axis maximum value used to display the monitor set in o1-25 [Custom Monitor 2]
as a trend plot. This parameter is only available on an HOA keypad.
V/f
OLV/PM EZOLV
OLV/PM
Sets the time scale (horizontal axis) to display the trend plot. When you change this setting, the drive
automatically adjusts the data sampling time. This parameter is only available on an HOA keypad.
V/f
OLV/PM EZOLV
OLV/PM
Sets the range used to display the monitor set in o1-24 [Custom Monitor 1] as an analog gauge. This
parameter is only available on an HOA keypad.
V/f
OLV/PM EZOLV
OLV/PM
Sets the value used to display the monitor set in o1-24 [Custom Monitor 1] as an analog meter. This
parameter is only available on an HOA keypad.
Description
Description
Description
Description
Description
Description
Description
YASKAWA TOEPYAIHV6002A HV600 Drive Programming
Default
(Range)
-100.0%
(-300.0 - +300.0%)
Default
(Range)
100.0%
(-300.0 - +300.0%)
Default
(Range)
-100.0%
(-300.0 - +300.0%)
Default
(Range)
100.0%
(-300.0 - +300.0%)
Default
(Range)
300 s
(1 - 3600 s)
Default
(Range)
1
(0, 1)
Default
(Range)
100.0%
(0.0 - 100.0%)