YASKAWA HV600 Manual page 28

Ac drive for hvac fan and pump applications
Hide thumbs Also See for HV600:
Table of Contents

Advertisement

1.5 b: Application
No.
Name
(Hex.)
b3-03
Speed Search
Deceleration Time
(0193)
b3-04
V/f Gain during Speed
Search
(0194)
b3-05
Speed Search Delay Time
(0195)
b3-06
Speed Estimation Current
Level 1
(0196)
Expert
b3-07
Speed Estimation Current
Level 2
(0197)
Expert
b3-08
Speed Estimation ACR P
Gain
(0198)
b3-09
Speed Estimation ACR I
Time
(0199)
b3-10
Speed Estimation
Detection Gain
(019A)
Expert
b3-11
Spd Est Method Switch-
over Level
(019B)
Expert
b3-12
Speed Search Current
Deadband
(019C)
Expert
b3-14
Bi-directional Speed
Search
(019E)
b3-17
Speed Est Retry Current
Level
(01F0)
Expert
28
V/f
OLV/PM
OLV/PM EZOLV
Sets the deceleration time during Speed Search operation. Set the length of time to
decelerate from the maximum output frequency to the minimum output frequency.
Note:
When A1-02 = 8 [Control Method Selection = EZOLV], this parameter takes effect
only in Expert Mode.
V/f
OLV/PM EZOLV
OLV/PM
Sets the ratio used to reduce the V/f during searches to reduce the output current during
speed searches.
V/f
OLV/PM EZOLV
OLV/PM
Sets the Speed Search delay time to activate a magnetic contactor installed between the
drive and motor.
V/f
OLV/PM EZOLV
OLV/PM
Sets the level of current that flows to the motor during Speed Estimation Speed Search as a
coefficient of the motor rated current. Usually it is not necessary to change this setting.
V/f
OLV/PM EZOLV
OLV/PM
Sets the level of current that flows to the motor during Speed Estimation Speed Search as a
coefficient of E2-03 [Motor No-Load Current] or E4-03 [Motor 2 Rated No-Load
Current]. Usually it is not necessary to change this setting.
V/f
OLV/PM EZOLV
OLV/PM
Sets the proportional gain for the automatic current regulator during Speed Estimation
Speed Search. Also adjusts speed search responsiveness. Usually it is not necessary to
change this setting.
V/f
OLV/PM EZOLV
OLV/PM
Sets the integral time for the automatic current regulator during Speed Estimation Speed
Search. Also adjusts speed search responsiveness. Usually it is not necessary to change this
setting.
V/f
OLV/PM
OLV/PM EZOLV
Sets the gain to correct estimated frequencies from Speed Estimation Speed Search.
Note:
When A1-02 = 8 [Control Method Selection = EZOLV], the default setting is 1.00 and
the setting range is 1.00 - 1.10.
V/f
OLV/PM EZOLV
OLV/PM
Uses the quantity of voltage in the motor to automatically switch the search method within
the type of speed measurement.
Note:
• 208 V class at 100% = 200 V
• 480 V class at 100% = 400 V
V/f
OLV/PM
OLV/PM EZOLV
Sets the minimum current detection level during Speed Search. If the drive does not do
Speed Estimation, increase this setting in 0.1-unit increments.
V/f
OLV/PM EZOLV
OLV/PM
Sets the direction of Speed Search to the direction of the frequency reference or in the
motor rotation direction as detected by the drive.
0 : Disabled
1 : Enabled
Note:
• Refer to page
146
for information about the initial value of b3-14 that applies when
you set these parameters:
–A1-02 = 0, 8 [Control Method Selection = V/f, EZOLV]
–E9-01 = 0 [Motor Type Selection = Induction (IM)]
–b3-24 = 1 [Speed Search Method Selection = Speed Estimation Speed Search]
• The initial value of b3-14 is 0 when you set these parameters:
–A1-02 = 0, 8
–E9-01 = 0
–b3-24 = 2 [Current Detection 2]
• Refer to page
146
for information about the initial value of b3-14 that applies when
you set these parameters:
–A1-02 = 8 [EZOLV]
–E9-01 = 1, 2 [Permanent Magnet (PM), Synchronous Reluctance (SynRM)]
• When you change A1-02, b3-24, and E9-01, also set b3-14.
V/f
OLV/PM EZOLV
OLV/PM
Sets the current level for the search retry function in Speed Estimation Speed Search as a
percentage where drive rated current is a setting value of 100%.
Description
YASKAWA TOEPYAIHV6002A HV600 Drive Programming
Default
Ref.
(Range)
2.0 s
194
(0.1 - 10.0 s)
Determined by o2-04
194
(10 - 100)
0.2 s
194
(0.0 - 100.0 s)
Determined by o2-04
194
(0.0 - 2.0)
1.0
195
(0.0 - 3.0)
Determined by A1-02 and
195
o2-04
(0.00 - 6.00)
Determined by A1-02
195
when A1-02 ≠ 5
20.0 when A1-02 = 5
(0.0 - 1000.0 ms)
1.05
195
(1.00 - 1.20)
5.0%
195
(0.5 - 100.0%)
determined by o2-04
195
(2.0 - 10.0)
Determined by A1-02 and
196
b3-24
(0, 1)
110%
196
(0 - 200%)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents