A: Initialization Parameters

A1: Initialization

No.
Name
(Hex.)
A1-00
Language Selection
(0100)
RUN
A1-01
Access Level Selection
(0101)
RUN
A1-02
Control Method Selection
(0102)
A1-03
Initialize Parameters
(0103)
A1-04
Password
(0104)
A1-05
Password Setting
(0105)
A1-06
Application Preset
(0127)
A1-07
DriveWorksEZ Function
Selection
(0128)
A1-11
Firmware Update Lock
(111D)
Expert
A1-12
Bluetooth ID
(1564)
YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING
Sets the language for the LCD keypad.
Note:
When you use A1-03 [Initialize Parameters] to initialize the drive, the drive will not reset this
parameter.
0 : English
1 : Japanese
2 : German
3 : French
4 : Italian
5 : Spanish
6 : Portuguese
7 : Chinese
8 : Czech
9 : Russian
10 : Turkish
11 : Polish
12 : Greek
Sets user access to parameters. The access level controls which parameters the keypad will display,
and which parameters the user can set.
0 : Operation Only
1 : User Parameters
2 : Advanced Level
3 : Expert Level
Sets the control method for the drive application and the motor.
0 : V/f Control
2 : Open Loop Vector
5 : PM Open Loop Vector
6 : PM Advanced Open Loop Vector
8 : EZ Vector Control
Sets parameters to default values.
0 : No Initialization
1110 : User Initialization
2220 : 2-Wire Initialization
3330 : 3-Wire Initialization
Entry point for the password set in A1-05 [Password Setting]. The user can view the settings of
parameters that are locked without entering the password. Enter the correct password in this
parameter to change parameter settings.
Set the password to lock parameters and prevent changes to parameter settings. Enter the correct
password in A1-04 [Password] to unlock parameters and accept changes.
Sets the drive to operate in selected application conditions.
0 : General-purpose
1 : Water Supply Pump 2
2 : Conveyor
3 : Exhaust Fan
4 : HVAC Fan
5 : Air Compressor
8 : Conveyor 2
Sets the drive to operate with DriveWorksEZ.
0 : DWEZ Disabled
1 : DWEZ Enabled
2 : Enabled/Disabled wDigital Input
Protects the drive firmware. When you enable the protection, you cannot update the drive firmware.
0 : Disabled
1 : Enabled
Sets the password necessary to use Bluetooth to control the drive with a smartphone or tablet.

3.4 A: Initialization Parameters

Description
Default
(Range)
0
(0 - 12)
2
(0 - 3)
2
(0, 2, 5, 6, 8)
0
(0 - 3330)
0000
(0000 - 9999)
0000
(0000 - 9999)
0
(0 - 5, 8)
3
0
(0 - 2)
0
(0, 1)
-
(0000 - 9999)