1.18 U: Monitors
No.
Name
(Hex.)
U3-12
ElapsedTime@2ndFault
(0095)
U3-13
ElapsedTime@3rdFault
(0096)
U3-14
ElapsedTime@4thFault
(0097)
U3-15
ElapsedTime@5thFault
(080E)
U3-16
ElapsedTime@6thFault
(080F)
U3-17
ElapsedTime@7thFault
(0810)
U3-18
ElapsedTime@8thFault
(0811)
U3-19
ElapsedTime@9thFault
(0812)
U3-20
ElapsedTime@10 Fault
(0813)
U3-21
Fault 1 YYYY
(300B)
U3-22
Fault 1 MMDD
(300C)
U3-23
Fault 1 HHMM
(300D)
U3-24
Fault 2 YYYY
(300E)
U3-25
Fault 2 MMDD
(300F)
U3-26
Fault 2 HHMM
(3010)
U3-27
Fault 3 YYYY
(3011)
U3-28
Fault 3 MMDD
(3012)
U3-29
Fault 3 HHMM
(3013)
U3-30
Fault 4 YYYY
(3014)
U3-31
Fault 4 MMDD
(3015)
118
V/f
OLV/PM
OLV/PM EZOLV
Shows the cumulative operation time when the second most recent fault occurred.
Note:
The drive saves this cumulative operation time to two types of registers at the same time for the
MEMOBUS/Modbus communications.
Unit: 1 h
V/f
OLV/PM
OLV/PM EZOLV
Shows the cumulative operation time when the third most recent fault occurred.
Note:
The drive saves this cumulative operation time to two types of registers at the same time for the
MEMOBUS/Modbus communications.
Unit: 1 h
V/f
OLV/PM EZOLV
OLV/PM
Shows the cumulative operation time when the fourth most recent fault occurred.
Note:
The drive saves this cumulative operation time to two types of registers at the same time for the
MEMOBUS/Modbus communications.
Unit: 1 h
V/f
OLV/PM EZOLV
OLV/PM
Shows the cumulative operation time when the fifth most recent fault occurred.
Unit: 1 h
V/f
OLV/PM
OLV/PM EZOLV
Shows the cumulative operation time when the sixth most recent fault occurred.
Unit: 1 h
V/f
OLV/PM
OLV/PM EZOLV
Shows the cumulative operation time when the seventh most recent fault occurred.
Unit: 1 h
V/f
OLV/PM EZOLV
OLV/PM
Shows the cumulative operation time when the eighth most recent fault occurred.
Unit: 1 h
V/f
OLV/PM EZOLV
OLV/PM
Shows the cumulative operation time when the ninth most recent fault occurred.
Unit: 1 h
V/f
OLV/PM EZOLV
OLV/PM
Shows the cumulative operation time when the tenth most recent fault occurred.
Unit: 1 h
V/f
OLV/PM EZOLV
OLV/PM
Shows the year when the most recent fault occurred.
V/f
OLV/PM
OLV/PM EZOLV
Shows the month and day when the most recent fault occurred.
V/f
OLV/PM
OLV/PM EZOLV
Shows the time when the most recent fault occurred.
V/f
OLV/PM
OLV/PM EZOLV
Shows the year when the second most recent fault occurred.
V/f
OLV/PM
OLV/PM EZOLV
Shows the month and day when the second most recent fault occurred.
V/f
OLV/PM EZOLV
OLV/PM
Shows the time when the second most recent fault occurred.
V/f
OLV/PM EZOLV
OLV/PM
Shows the year when the third most recent fault occurred.
V/f
OLV/PM EZOLV
OLV/PM
Shows the month and day when the third most recent fault occurred.
V/f
OLV/PM EZOLV
OLV/PM
Shows the time when the third most recent fault occurred.
V/f
OLV/PM EZOLV
OLV/PM
Shows the year when the fourth most recent fault occurred.
V/f
OLV/PM EZOLV
OLV/PM
Shows the month and day when the fourth most recent fault occurred.
Description
YASKAWA TOEPYAIHV6002A HV600 Drive Programming
MFAO Signal Level
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available