2.8 H: Terminal Functions
A9: RELAY Operator Control
Setting Value
Function
A9
RELAY Operator Control
AA: Utility Delay
Setting Value
Function
AA
Utility Delay
AB: Thrust Mode
Setting Value
Function
AB
Thrust Mode
AC: Setpoint Not Maintained
Setting Value
Function
AC
Setpoint Not Maintained
B2: BAS Interlock
Setting Value
Function
B2
BAS Interlock
B8: Pump Fault
Setting Value
Function
B8
Pump Fault
B9: Transducer Loss
Setting Value
Function
B9
Transducer Loss
BA: PI Auxiliary Control Active
Setting Value
Function
BA
PI Auxiliary Control Active
BB: Differential Feedback Exceeded
Setting Value
Function
BB
Differential Feedback
Exceeded
322
V/f
OLV/PM
OLV/PM EZOLV
The terminal changes to OFF or ON when you push the RELAY (
it OFF. When the terminal is OFF, push
V/f
OLV/PM EZOLV
OLV/PM
The terminal activates when the drive is stopped and is waiting for the timer set in Y4-17 [Utility Start Delay] to expire.
V/f
OLV/PM
OLV/PM EZOLV
The terminal activates when the output frequency is between 0.0 Hz and the value set in Y4-12 [Thrust Frequency] and the Thrust
Bearing function is active.
V/f
OLV/PM EZOLV
OLV/PM
The terminal activates when the drive detects NMS [Setpoint Not Met] condition.
V/f
OLV/PM EZOLV
OLV/PM
The terminal activates when the Run command is active or the drive is outputting the voltage. The drive will use this as an actuation
signal for an external damper.
V/f
OLV/PM EZOLV
OLV/PM
The terminal activates when one of these faults is active: LFB [Low Feedback Sensed], HFB [High Feedback Sensed], NMS
[Setpoint Not Met], or EFx [External Fault (Terminal Sx)].
V/f
OLV/PM
OLV/PM EZOLV
The terminal activates when the current into the analog input associated with PID feedback is more than 21 mA or less than 3 mA,
or an FDBKL [WIRE Break] Fault or an FDBKL [Feedback Loss Wire Break] Alarm is active.
V/f
OLV/PM EZOLV
OLV/PM
The terminal activates when the PI Auxiliary Controller has an effect on the output speed.
V/f
OLV/PM EZOLV
OLV/PM
The terminal activates when the difference between the PID Feedback and the value from the terminal set for H3-xx = 2D
[Differential Feedback] is more than Y4-18 [Differential Level] for the time set in Y4-19 [Differential Lvl Detection Time].
Description
) button. When the terminal is ON, push
to turn in ON.
Description
Description
Description
Description
Description
Description
Description
Description