YASKAWA HV600 Manual page 63

Ac drive for hvac fan and pump applications
Hide thumbs Also See for HV600:
Table of Contents

Advertisement

Setting Value
Function
4B
During Short Circuit
Braking
4C
During Fast Stop
4D
oH Pre-Alarm Reduction
Limit
51
Sequence Timer 1
52
Sequence Timer 2
53
Sequence Timer 3
54
Sequence Timer 4
58
UL6 Underload Detected
60
Internal Cooling Fan
Failure
61
Pole Position Detection
Complete
62
Modbus Reg 1 Status
Satisfied
63
Modbus Reg 2 Status
Satisfied
69
External Power 24V
Supply
6A
Data Logger Error
71
Low PI2 Control
Feedback Level
72
High PI2 Control
Feedback Level
89
Output Current Lim
90
DWEZ Digital Outputs 1
91
DWEZ Digital Outputs 2
92
DWEZ Digital Outputs 3
94
Loss of Prime
95
Thermostat Fault
96
High Feedback
YASKAWA TOEPYAIHV6002A HV600 Drive Programming
V/f
OLV/PM
OLV/PM EZOLV
The terminal activates during Short Circuit Braking.
Note:
When A1-02 = 8 [Control Method Selection = EZOLV], this function is available only when you use a PM motor.
V/f
OLV/PM EZOLV
OLV/PM
The terminal activates when the fast stop is in operation.
V/f
OLV/PM EZOLV
OLV/PM
The terminal activates when L8-03 = 4 [Overheat Pre-Alarm Selection = Operate at Reduced Speed (L8-19)] and oH
[Heatsink Overheat] does not clear after the drive decreases the frequency for 10 cycles.
V/f
OLV/PM EZOLV
OLV/PM
The terminal activates when Sequence Timer 1 is active.
V/f
OLV/PM
OLV/PM EZOLV
The terminal activates when Sequence Timer 2 is active.
V/f
OLV/PM
OLV/PM EZOLV
The terminal activates when Sequence Timer 3 is active.
V/f
OLV/PM EZOLV
OLV/PM
The terminal activates when Sequence Timer 4 is active.
V/f
OLV/PM EZOLV
OLV/PM
The terminal activates when the drive detected UL6 [Underload or Belt Break Detected].
V/f
OLV/PM
OLV/PM EZOLV
The terminal activates when the drive detects a cooling fan failure in the drive.
V/f
OLV/PM EZOLV
OLV/PM
The terminal activates when drive receives a Run command and the drive detects the motor magnetic pole position of
the PM motor.
V/f
OLV/PM EZOLV
OLV/PM
The terminal activates when the bit specified by H2-08 [Modbus Register 1 Bit Select] for the MEMOBUS register
address set with H2-07 [Modbus Register 1 Address Select] activates.
V/f
OLV/PM
OLV/PM EZOLV
The terminal activates when the bit specified by H2-10 [Modbus Register 2 Bit Select] for the MEMOBUS register
address set with H2-09 [Modbus Register 2 Address Select] activates.
V/f
OLV/PM EZOLV
OLV/PM
The terminal activates when there is an external 24V power supply between terminals PS-AC.
ON : An external 24V power supply supplies power.
OFF : An external 24V power supply does not supply power.
V/f
OLV/PM EZOLV
OLV/PM
The terminal activates when the drive detects a LoG [Com Error / Abnormal SD card].
V/f
OLV/PM
OLV/PM EZOLV
The terminal activates when the PI2 Control Feedback Level is less than S3-13 [PI2 Control Low Feedback Lvl].
V/f
OLV/PM
OLV/PM EZOLV
The terminal activates when the PI2 Control Feedback Level is more than S3-15 [PI2 Control High Feedback Lvl].
V/f
OLV/PM
OLV/PM EZOLV
The terminal activates when the output current limit is limiting the drive output speed.
V/f
OLV/PM EZOLV
OLV/PM
Sets the digital output 1 to use in DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
V/f
OLV/PM
OLV/PM EZOLV
Sets the digital output 2 to use in DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
V/f
OLV/PM EZOLV
OLV/PM
Sets the digital output 3 to use in DriveWorksEZ. Refer to the DriveWorksEZ online manual for more information.
V/f
OLV/PM
OLV/PM EZOLV
The terminal activates when the drive is in an LOP [Loss of Prime] condition.
V/f
OLV/PM EZOLV
OLV/PM
The terminal activates when the terminal set for H1-xx = 88 [MFDI Function Selection = Thermostat Fault] is active.
V/f
OLV/PM EZOLV
OLV/PM
The terminal activates when the drive is in a High Feedback Condition as specified by Y1-11 [High Feedback Level]
and Y1-12 [High Feedback Lvl Fault Dly Time] and when the drive detects an HFB [High Feedback Sensed] fault or
an HIFB [High Feedback Sensed] alarm.
1.10 H: Terminal Functions
Description
Ref.
319
319
319
319
319
319
320
320
320
320
320
320
320
320
320
321
321
321
321
321
321
1
321
321
63

Hide quick links:

Advertisement

Table of Contents
loading