No.
Name
(Hex.)
o2-24
LED Light Function
Selection
(11FE)
o2-26
Alarm display at ext. 24V
power
(1563)
o2-27
bCE Detection Selection
(1565)

o3: Copy Keypad Function

No.
Name
(Hex.)
o3-01
Copy Keypad Function
Selection
(0515)
o3-02
Copy Allowed Selection
(0516)
o3-04
Select Backup/Restore
Location
(0B3E)
o3-05
Select Items to Backup/
Restore
(0BDA)
YASKAWA TOEPYAIHV6002A HV600 Drive Programming
Description
V/f
OLV/PM
OLV/PM EZOLV
Sets the function to show the LED status rings and keypad LED lamps.
Note:
When you use A1-03 [Initialize Parameters] to initialize the drive, the drive will not
reset this parameter.
0 : Enable Status Ring & Keypad LED
1 : LED Status Ring Disable
2 : Keypad LED Light Disable
V/f
OLV/PM
OLV/PM EZOLV
When you connect a backup external 24 V power supply, this parameter sets the function
to trigger an alarm when the main circuit power supply voltage decreases.
Note:
The drive will not run when it is operating from one 24-V external power supply.
0 : No
1 : Yes
V/f
OLV/PM
OLV/PM EZOLV
Sets drive operation if the Bluetooth device is disconnected when you operate the drive in
Bluetooth Mode.
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : No Alarm Display
Description
V/f
OLV/PM
OLV/PM EZOLV
Sets the function that saves and copies drive parameters to a different drive with the
keypad.
0 : Copy Select
1 : Backup (drive → keypad)
2 : Restore (keypad → drive)
3 : Verify (check for mismatch)
4 : Erase (backup data of keypad)
V/f
OLV/PM
OLV/PM EZOLV
Sets the copy function when o3-01 = 1 [Copy Keypad Function Selection = Backup (drive
→ keypad)].
0 : Disabled
1 : Enabled
V/f
OLV/PM EZOLV
OLV/PM
Sets the storage location for drive parameters when you back up and restore parameters.
This parameter is only available on an HOA keypad.
0 : Memory Location 1
1 : Memory Location 2
2 : Memory Location 3
3 : Memory Location 4
V/f
OLV/PM EZOLV
OLV/PM
Sets which parameters the drive backs up, restores, and references. This parameter is only
available on an HOA keypad.
0 : Standard Parameters
1 : Standard + DWEZ Parameters
1.13 o: Keypad-Related Settings
Default
(Range)
2
(0 - 2)
1
(0, 1)
3
(0 - 4)
Default
(Range)
0
(0 - 4)
0
(0, 1)
0
(0 - 3)
1
(0, 1)
Ref.
418
418
419
Ref.
419
419
420
420
1
95