1.18 U: Monitors

UA: Network Multiplexing

No.
Name
(Hex.)
UA-01
Network PID Feedback
(1EC1)
UA-02
Network Activity
(1EC2)
UA-03
Time to Alternation
(1EC3)
UA-04
Running Queue No
(1EC4)

UC: BACnet Diagnostic Monitors

No.
Name
(Hex.)
UC-01
BN MSTP Net Health
(3DB0)
UC-02
BACnet Tokens Rx
(3DB1)
UC-03
BACnet Tokens Tx
(3DB2)
UC-04
BACnet Messages Rx
(3DB3)
UC-05
BACnet Messages Tx
(3DB4)
UC-06
MSTP Next Node Addr
(3DB5)
UC-07
MSTP Prev Node Addr
(3DB6)
UC-08
MSTP H MAC Found
(3DB7)
UC-09
MSTP L MAC Found
(3DB8)
UC-10
MSTP # Nodes Found
(3DB9)
130
V/f
OLV/PM EZOLV
OLV/PM
Shows the Network PID Feedback recognized by the MEMOBUS Network.
Note:
Parameters b5-46 [PID Unit Display Selection], b5-38 [PID User Unit Display Scaling], and b5-
39 [PID User Unit Display Digits] set the unit, range, and resolution.
Unit: 0.01%
V/f
OLV/PM EZOLV
OLV/PM
Shows network traffic. When this number changes between 0.0% to 100.0%, there is activity. When
the number stays near 0.0%, there is no activity.
The unit is followed by an identifier that changes as specified by network status:
• <->: Drive cannot communicate to other drives
• <+>: Drive is a Node on a network
• <M>: Drive is the Master on an Network
Unit: 0.1%
V/f
OLV/PM EZOLV
OLV/PM
Shows the how much time until the drive requests alternation. This is specified in Y9-04 [Alternation
Mode].
Unit: 1 min
V/f
OLV/PM EZOLV
OLV/PM
Shows the position in the MEMOBUS Multiplex Running Queue.
V/f
OLV/PM EZOLV
OLV/PM
Shows a number between 0.0% and 100.0% that identifies the health of the MSTP network. This
number is dependent on the number of CRC errors, token losses, token retries, and net deadtime
perceived.
Unit: 0.1%
V/f
OLV/PM
OLV/PM EZOLV
Shows the number of received MSTP Tokens after you energize the drive.
Unit: 1
V/f
OLV/PM
OLV/PM EZOLV
Shows the number of transmitted MSTP Tokens after you energize the drive.
Unit: 1
V/f
OLV/PM
OLV/PM EZOLV
Shows the number of messages with data (non-token, non-polling) received by the drive.
Unit: 1
V/f
OLV/PM
OLV/PM EZOLV
Shows the number of messages with data (non-token, non-polling) transmitted by the drive.
Unit: 1
V/f
OLV/PM
OLV/PM EZOLV
Shows the next known node in the MSTP loop. This is the node to which the drive will pass the
token.
V/f
OLV/PM
OLV/PM EZOLV
Shows the previous known node in the MSTP loop. This is the node from which the drive received
the token.
V/f
OLV/PM EZOLV
OLV/PM
Shows the highest MAC address found on the network. This will report the highest value MAC
address to which the token was passed by any node on the MSTP loop.
V/f
OLV/PM
OLV/PM EZOLV
Shows the lowest MAC address found on the network. This will report the lowest value MAC
address to which the token was passed by any node on the MSTP loop.
V/f
OLV/PM EZOLV
OLV/PM
Shows the number of unique nodes that transmitted a token on the local MSTP loop.
Unit: 1
Description
Description
YASKAWA TOEPYAIHV6002A HV600 Drive Programming
MFAO Signal Level
No signal output available
No signal output available
No signal output available
No signal output available
MFAO Signal Level
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available

Hide quick links: