012-132 (Integrated Finisher) Entrance Sensor ON Jam
RAP
BSD-ON:
BSD 12.3 Integrated Finisher Transportation
Finisher Entrance Sensor does not turn On within a specified time after receiving the Sheet
Exit command (the sheet to be ejected has turned ON the IOT Exit Sensor 1).
Initial Actions
Check that the Finisher Entrance Sensor is properly installed and free from foreign
objects and that the actuator is not broken.
Power Off/On.
Procedure
Check the specifications of paper. Paper is in spec.
Y
N
Replace the paper with new paper that is in spec.
Check the condition of the paper. The paper is in normal condition without any problem
that causes the paper to be bent or caught.
Y
N
Resolve any problem that causes the paper to be bent or caught.
Check the transport path for a foreign object, deformed part, and paper dust. The
path is in normal condition.
Y
N
Repair the deformed part(s) and remove the foreign object(s) and paper dust.
Check that the Finisher is installed properly. The Finisher is properly installed and properly
connected to the IOT.
Y
N
Reinstall the Finisher properly.
Enter
Component Control
[012-140]. Actuate the Finisher Entrance Sensor. The
changes.
Y
N
Check the connections of
P/J8709
and P/J8729.
connected.
Y
N
Connect
P/J8709
and
P/J8729
Check for an open or short circuit between
P/J8709
and
P/J8729
are OK.
Y
N
Repair the open or short circuit.
Measure the voltage between Finisher PWB P/J8709-6 (+) and GND (-). The voltage is
approx. +5VDC.
Y
N
Go to
Integrated Finisher Wirenets
A
B
Initial Issue
WorkCentre 5335 Family Service Documentation
transport
P/J8709
and
P/J8729
are securely
securely.
P/J8709
and P/J8729. The wires between
and check the +5VDC circuit.
BUS Updated 12/2011
A
B
Measure the voltage between Finisher PWB P/J8709-5 (+) and GND (-). Actuate the Fin-
isher Entrance Sensor. The voltage changes.
Y
N
Replace the Finisher Entrance Sensor
Check the wires and connectors for an intermittent open or short circuit. If the problem
continues, replace the Finisher PWB
Check the wires and connectors for an intermittent open or short circuit. If the problem contin-
ues, replace the Finisher PWB
display
07/2011
2-87
(PL
22.5).
(PL
22.7).
(PL
22.7).
Status Indicator RAPs
012-132 (Integrated Finisher)