003-321 IISS-ESS Communication 2 RAP

BSD-ON:
BSD 3.3 - ESS-IIT Communication
BSD-ON:
BSD 16.1 - ESS
The ACK (acknowledgement code) could not be received after 2 resend attempts. (The
Sequencing No. of the sent Message Packet is incorrect.) Error detected when information
sent to controller from IIT via IIT CDI I/F during initialization of controller is insufficient. (e.g. bad
combination of controller SW and IIT SW).
Procedure
Disconnect and reconnect the IIT Harness
Reload Software
(GP
16).
If the problem persists, replace the IIT PWB (Switch the EEPROM)
Replace the ESS PWB
(PL
35.2)
Initial Issue
WorkCentre 5335 Family Service Documentation
(PL
1.6).
(PL
1.6).
BUS Updated 12/2011

003-322 IISS-ESS Communication 3 RAP

BSD-ON:
BSD 3.3 - ESS-IIT Communication
BSD-ON:
BSD 16.1 - ESS
The ACK (acknowledgement code) could not be received after 2 resend attempts. (The Packet
No. of the sent Message Packet is incorrect.)
Procedure
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Disconnect then reconnect the IIT, Control Panel, ESS, MCU all PWBs connected to them
(RAM, Firmware module, EEPROM)
Reload Software
(GP
16)
Replace IIT PWB (Switch the EEPROM)
If the problem persists, replace the ESS PWB
original ESS PWB and RAM DIMM.)
07/2011
2-25
(PL
1.6)
(PL
35.2). (If not fixed by this, reinstall the
Status Indicator RAPs
003-321, 003-322