003-321 IISS-ESS Communication 2 RAP
BSD-ON:
BSD 3.3 - ESS-IIT Communication
BSD-ON:
BSD 16.1 - ESS
The ACK (acknowledgement code) could not be received after 2 resend attempts. (The
Sequencing No. of the sent Message Packet is incorrect.) Error detected when information
sent to controller from IIT via IIT CDI I/F during initialization of controller is insufficient. (e.g. bad
combination of controller SW and IIT SW).
Procedure
•
Disconnect and reconnect the IIT Harness
•
Reload Software
(GP
16).
•
If the problem persists, replace the IIT PWB (Switch the EEPROM)
•
Replace the ESS PWB
(PL
35.2)
Initial Issue
WorkCentre 5335 Family Service Documentation
(PL
1.6).
(PL
1.6).
BUS Updated 12/2011
003-322 IISS-ESS Communication 3 RAP
BSD-ON:
BSD 3.3 - ESS-IIT Communication
BSD-ON:
BSD 16.1 - ESS
The ACK (acknowledgement code) could not be received after 2 resend attempts. (The Packet
No. of the sent Message Packet is incorrect.)
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the IIT, Control Panel, ESS, MCU all PWBs connected to them
(RAM, Firmware module, EEPROM)
•
Reload Software
(GP
16)
•
Replace IIT PWB (Switch the EEPROM)
•
If the problem persists, replace the ESS PWB
original ESS PWB and RAM DIMM.)
07/2011
2-25
(PL
1.6)
(PL
35.2). (If not fixed by this, reinstall the
Status Indicator RAPs
003-321, 003-322