003-333 IISS-ESS Communication 14 RAP

BSD-ON:
BSD 3.3 - ESS-IIT Communication
BSD-ON:
BSD 16.1 - ESS
The NAK (Negative Acknowledgement) that notifies of the occurrence of a transmission failure
is received. (A parity error was detected by hardware of the UART.)
Procedure
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Disconnect then reconnect the IIT, Control Panel, ESS, MCU all PWBs connected to them
(RAM, Firmware module, EEPROM)
Reload Software
(GP
16)
Replace IIT PWB (Switch the EEPROM)
If the problem persists, replace the ESS PWB
original ESS PWB and RAM DIMM.)
Initial Issue
WorkCentre 5335 Family Service Documentation
(PL
1.6)
(PL
35.2). (If not fixed by this, reinstall the
BUS Updated 12/2011

003-334 IISS-ESS Communication 15 RAP

BSD-ON:
BSD 3.3 - ESS-IIT Communication
BSD-ON:
BSD 16.1 - ESS
The NAK (Negative Acknowledgement) that notifies of the occurrence of a transmission failure
is received. (A framing error was detected by hardware of the UART.)
Procedure
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Disconnect then reconnect the IIT, Control Panel, ESS, MCU all PWBs connected to them
(RAM, Firmware module, EEPROM)
Reload Software
(GP
16)
Replace IIT PWB (Switch the EEPROM)
If the problem persists, replace the ESS PWB
original ESS PWB and RAM DIMM.)
07/2011
2-31
(PL
1.6)
(PL
35.2). (If not fixed by this, reinstall the