003-753 300dpi Cannot be Scanned RAP

BSD-ON:
BSD 3.5 - ESS-DADF Communication
This status code is displayed if - Unscannable 300dpi or higher resolution detected after DADF
Mix Duplex Mode Job is accepted.
Procedure
Perform scanning below 200 dpi resolution.
Or perform scanning in other than mixed mode.
If powering OFF then ON does not resolve the problem, perform the following:
1.
Check the connection between IIT PWB and ESS PWB.
2.
Check the sw version of the controller sw - reload Software
3.
Replace IIT PWB (Switch the EEPROM)
4.
Replace ESS PWB
(PL
35.2).
Status Indicator RAPs
003-753, 003-754
(GP
16)
(PL
1.6)
BUS Updated 12/2011

003-754 Scan Recoverable Error RAP

BSD-ON:
BSD 3.5 - ESS-DADF Communication
Recoverable high-compression Scan error
Procedure
Retry the job.
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
Check the sw version of the controller sw - reload Software
07/2011
2-40
(GP
16)
Initial Issue
WorkCentre 5335 Family Service Documentation