012-291 (Integrated Finisher) Stapler Fail RAP

BSD-ON:
BSD 12.5 - Integrated Finisher Staple Control
Within a specified time after the Staple Motor started rotating in reverse direction, the Staple
Head Home Sensor was never detected turning On.
Initial Actions
Check that the Staple Assembly and the Cartridge are properly installed, not broken and
include no foreign objects.
Power Off/ON.
Procedure
Enter
Component Control
[012-046] and [012-047] alternately. The Staple Motor rotates.
Y
N
Check the connections of
P/J8705
and P/J8735.
connected.
Y
N
Connect
P/J8705
and
P/J8735
Check for an open or short circuit between
P/J8705
and
P/J8735
are OK.
Y
N
Repair the open wire or short circuit.
Enter [012-046] and [012-047] alternately. Measure the voltages between Finisher PWB
P/J8705-3, 4, 5, 6 (+) and GND (-). Each voltage changes.
Y
N
Check the wires and connectors for an intermittent open or short circuit. If the prob-
lem continues, replace the Finisher PWB
Replace the Staple Assembly
(PL
22.4).
Enter [012-046] and [012-047] alternately. The display changes.
Y
N
Check the connections of
P/J8701
and P/J8731.
connected.
Y
N
Connect
P/J8701
and
P/J8731
Check for an open or short circuit between
P/J8701
and
P/J8731
are OK.
Y
N
Repair the open or short circuit.
Measure the voltage between Finisher PWB P/J8701-9 (+) and GND (-). The voltage is
approx. +5VDC.
Y
N
Go to
Integrated Finisher Wirenets
A
B
Initial Issue
WorkCentre 5335 Family Service Documentation
P/J8705
and
P/J8735
are securely
securely.
P/J8705
and P/J8735. The wires between
(PL
22.7)
P/J8701
and
P/J8731
are securely
securely.
P/J8701
and P/J8731. The wires between
and check the +5VDC circuit.
BUS Updated 12/2011
A
B
Measure the voltage between Finisher PWB P/J8731-5 (+) and GND (-). Enter [012-046]
and [012-047] alternately. The voltage changes.
Y
N
Replace the Staple Assembly
Check the wires and connectors for an intermittent open or short circuit. If the problem
continues, replace the Finisher PWB
Check the wires and connectors for an intermittent open or short circuit. If the problem contin-
ues, replace the Finisher PWB
(PL
07/2011
2-101
(PL
22.4).
(PL
22.7).
22.7).
Status Indicator RAPs
012-291 (Integrated Finisher)