003-311 Iit Cdi Interface Mismatch Rap; 003-318 Iit Software Rap - Xerox workcentre 5335 series Service Manual

Table of Contents

Advertisement

003-311 IIT CDI Interface Mismatch RAP

BSD-ON:
BSD 3.3 - ESS-IIT Communication
BSD-ON:
BSD 16.1 - ESS
Error detected when information sent to controller from IIT via IIT CDI I/F during initialization of
controller is insufficient. (e.g. bad combination of controller SW and IIT SW)
Procedure
Reload correct Controller and IIT Software
Replace IIT PWB (Switch the EEPROM)
Replace the ESS PWB
(PL
35.2)
Initial Issue
WorkCentre 5335 Family Service Documentation
(GP
16).
(PL
1.6)
BUS Updated 12/2011

003-318 IIT Software RAP

BSD-ON:
BSD 3.3 - ESS-IIT Communication
BSD-ON:
BSD 16.1 - ESS
The IIT software is corrupt.
Procedure
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Disconnect then reconnect the IIT, Control Panel, ESS, MCU all PWBs connected to them
(RAM, Firmware module, EEPROM)
Check the sw version of the controller sw
Reload Software
(GP
16)
Replace IIT PWB (Switch the EEPROM)
If the problem persists, replace the ESS PWB
original ESS PWB and RAM DIMM.)
07/2011
2-23
(PL
1.6)
(PL
35.2). (If not fixed by this, reinstall the
Status Indicator RAPs
003-311 , 003-318

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 5335 series

Table of Contents