Figure 233: Installing A Power Supply In A Qfx3100 Director Device - Juniper QFabric QFX3000-G Hardware Documentation

Hide thumbs Also See for QFabric QFX3000-G:
Table of Contents

Advertisement

QFX3000-G QFabric System Hardware Documentation
Related
Documentation
Removing a Fan Module from a QFX3100 Director Device
590
Attach the ESD grounding strap to your bare wrist, and connect the strap to a site ESD
1.
point.
If the power supply slot has a power supply in it that needs to be removed, remove
2.
the power supply. See
"Removing a Power Supply from a QFX3100 Director Device
(includes video)" on page
Taking care not to touch power supply components, pins, leads, or solder connections,
3.
remove the power supply from its bag.
Using one hand on the faceplate handle and the other hand on the bottom of the
4.
power supply to support its weight, gently slide the power supply straight into the
power supply slot until the power supply reaches a point where backpressure prevents
the power supply from pushing forward; do not force the power supply fully into the
slot at this point of the procedure.
Use your thumb to move the ejector lever at the top of the power supply faceplate to
5.
the right, and push the power supply flush into the back of the chassis. Release the
latch.

Figure 233: Installing a Power Supply in a QFX3100 Director Device

Power
supply 2
Power
supply 1
Ejector
lever
Video:
Installing a Power Supply in a QFX3100 Director Device
AC Power Supply in a QFX3100 Director Device on page 34
AC Power Cord Specifications for a QFX3100 Director Device on page 277
Rear Panel of a QFX3100 Director Device on page 30
QFX3100 Director devices have three fan modules on the rear panel. The fan modules
are hot-removable and hot-insertable field-replaceable units (FRUs). You can remove
588.