Ensure that you have a power cord appropriate for your geographical location available
to connect AC power to the switch.
Before you begin connecting AC power to the switch:
Ensure that you have taken the necessary precautions to prevent electrostatic discharge
(ESD) damage (see
"Prevention of Electrostatic Discharge Damage" on page
Ensure that you have connected the switch chassis to earth ground.
CAUTION:
Before you connect power to the switch, a licensed electrician
must attach a cable lug to the grounding and power cables that you supply.
A cable with an incorrectly attached lug can damage the switch (for
example, by causing a short circuit).
To meet safety and electromagnetic interference (EMI) requirements and
to ensure proper operation, you must connect the chassis to earth ground
before you connect it to power. For installations that require a separate
grounding conductor to the chassis, use the protective earthing terminal
on the switch chassis to connect to the earth ground. For instructions on
connecting earth ground, see
Device" on page
the power supply in the switch into a grounded AC power outlet by using
the AC power cord appropriate for your geographical location (see
Power Supply for a QFX5100 Device" on page
Install the power supply in the chassis. For instructions on installing a power supply in
a QFX5100 device, see
"Installing a Power Supply in a QFX5100 Device" on page
NOTE:
Each power supply must be connected to a dedicated power source
outlet.
To connect AC power to a QFX5100 device:
Attach the grounding strap to your bare wrist and to a site ESD point.
1.
Ensure that the power supplies are fully inserted in the chassis and the latches are
2.
secure. If only one power supply is installed, ensure a that blank cover panel is installed
over the second power supply slot.
Locate the power cord or cords shipped with the switch; the cords have plugs
3.
appropriate for your geographical location. See
QFX Series Device" on page
WARNING:
Ensure that the power cord does not block access to device
components or drape where people can trip on it.
"Connecting Earth Ground to a QFX5100
442. The switch gains additional grounding when you plug
"AC Power Cord Specifications for a
292.