QFX3000-G QFabric System Hardware Documentation
Related
Documentation
Removing a QFX3008-I Interconnect Device from a Rack or Cabinet
576
Commit the changes using the
8.
the old device to the new device.
Connect the QFX3008-I Interconnect device to each Node device for data plane
9.
interconnection. See
"Connecting a QFX3600 Node Device to a QFX3008-I
Interconnect Device" on page 547
QFX3008-I Interconnect Device" on page
Verify the data plane interconnection using the show chassis fabric connectivity
10.
operational mode command from the QFabric default partition CLI. Repeat this
command if necessary until the new device is shown in the output.
Remove the previous QFX3008-I Interconnect device from the inventory of QFabric
11.
system components using the
device-name
operational mode command from the QFabric default partition CLI.
Example: Configuring the Virtual Chassis for a Copper-Based QFX3000-G QFabric System
Control Plane
Removing a QFX3008-I Interconnect Device from a Rack or Cabinet on page 576
If you want to move an installed QFX3008-I Interconnect device to another location, you
need to remove it from the rack or cabinet in which it is installed. An installed device rests
on the mounting shelf. In a four-post rack, the front-mounting brackets ("ears") attached
to the chassis are bolted to the rack. In a two-post rack, the mid-mounting brackets
("ears") attached to the chassis are bolted to the rack.
NOTE:
When you remove multiple devices from a rack or cabinet, remove
the device in the top of the rack or cabinet first and proceed to remove the
rest of the switches from top to bottom.
Before removing a QFX3008-I Interconnect device from a rack or a cabinet:
Ensure that the rack or cabinet is stable and secured to the building.
Ensure that there is enough space to place the removed device in its new location and
along the path to the new location.
Read
"General Safety Guidelines and Warnings" on page
to
"Chassis Lifting Guidelines for a QFX3008-I Interconnect Device" on page
Ensure that the device has been safely powered off (see
Interconnect Device" on page
power cords. Remove three-phase wiring trays from the chassis and move them
command, which sends the configuration of
commit
or
"Connecting a QFX3500 Node Device to a
548.
request fabric administration remove interconnect-device
562) and that you have unplugged (disconnected) the
Copyright © 2018, Juniper Networks, Inc.
329, with particular attention
338.
"Powering Off a QFX3008-I

Advertisement