Table 37: Fan Modules in EX4300 Switches

Fan Module
EX4300-FAN
EX4300-FAN-AFI
EX4300-48MP-FAN
Airflow Direction in EX4300 Switch Models
Copyright © 2018, Juniper Networks, Inc.
Figure 113: Fan Module Used in EX4300-48MP and EX4300-48MP-S Switches
You must remove only one fan module at a time for replacement from the rear panel of
the chassis. The switch continues to operate for a limited period of time (30 seconds)
during the replacement of the fan module without thermal shutdown.
NOTE:
Both the fan modules must be installed for optimal functioning of
the switch.
For EX4300 switches except EX4300-48MP and EX4300-48MP-S switches, the fan
modules are available in two models that have different airflow directions—back-to-front
(air enters through the back of the switch), indicated by label
front-to-back (air exhausts through the back of the switch), indicated by label
(AFO)
. For EX4300-48MP and EX4300-48MP-S switches, the fan module is available
in one model that has front-to-back (air exhausts through the back of the switch),
indicated by label
AIR OUT.
and the direction of airflow in them.
Table 38 on page 158
shows the direction of airflow in EX4300 switch models as shipped.
.
Table 37 on page 157
lists the available fan module models
Label on the Fan Module
AIR OUT (AFO)
AIR IN (AFI)
AIR OUT
Chapter 7: EX4300 Overview
, and
AIR IN (AFI)
AIR OUT
157